# Neodymium \(III\) chloride, anhydrous – ProChem SDS

Text extracted from the original PDF. Tables, images, symbols and OCR may differ. Check the original PDF for safety information.

- **Document title:** Neodymium \(III\) chloride, anhydrous – ProChem SDS
- **Publisher:** ProChem, Inc\.
- **Material:** Neodymium \(III\) chloride, anhydrous
- **CAS number:** 10024\-93\-8
- **Product code / grade:** 2633
- **Document type:** SDS
- **Original language:** English
- **Region:** United States
- **Revision date:** 05/14
- **Page count:** 4
- **Original filename:** prochem\-neodymiumchlorideanhydrous\-2633\.pdf
- **RESDS page:** https://resds\.com/document/neodymium\-iii\-chloride\-anhydrous\-prochem\-en\-69c68ad0f4
- **Original PDF:** https://resds\.com/pdf/neodymium\-iii\-chloride\-anhydrous\-prochem\-en\-69c68ad0f4\.pdf
- **Source URL:** https://prochemonline\.com/wp\-content/uploads/2021/06/2633\.NeodymiumChlorideAnhydrous\.pdf
- **Description:** Collected by RESDS\. Original publisher PDF retained\. Original ProChem SDS for Neodymium \(III\) chloride, anhydrous\. Product number 2633; revision 05/14\. Publication authorized by the user on 2026\-09\-14\.

## Page 1

```text
 SECTION 1     PRODUCT AND COMPANY INFORMATION

PRODUCT NAME:   Neodymium (III) chloride, anhydrous

PRODUCT NUMBER:  2633

CAS NUMBER:        10024-93-8

SYNONYMS:        Neodymium trichloride

MANUFACTURER:


Prochem, Inc.                                         PHONE:        815-398-1788
826 Roosevelt Road                                          FAX:           815-398-1810
Rockford, IL  61109                                     TOLL FREE:    800-795-8788

                   IN CASE OF TRANSPORTATION EMERGENCY CONTACT CHEM-TREC: 1-800-424-9300

SECTION 2    HAZARDS IDENTIFICATION

CLASSIFICATION OF SUBSTANCE OR MIXTURE



Pictogram


Signal Word         Warning

Hazard Statements


H303                Harmful if swallowed.
H315               Causes skin irritation.
H319               Causes serious eye irritation.
H335             May cause respiratory irritation.

Precautionary Phrases

P261                 Avoid breathing dust/fume/gas/mist/vapours/spray.
P305+P351+P338      IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to
                       do. Continue rinsing.
P303+P361+P353      IF ON SKIN (or hair): Remove/take off immediately all contaminated clothing. Rinse skin with water/shower.

HMIS CLASSIFICATION:
Health: 2            Flammability: 0                   Reactivity: 0
NFPA RATING:
Health: 2              Fire: 0                           Reactivity Hazard: 0

EYE CONTACT: May be a mild irritant to the eyes.
SKIN CONTACT: May cause slight irritation of the skin.
INHALATION: Inhalation of dust can lead to irritation of the respiratory tract.
INGESTION: May be harmful if swallowed.


NEODYMIUM (III) CHLORIDE, ANHYDROUS                                                          PAGE 1
```

## Page 2

```text
SECTION 3      COMPOSITION / INFORMATION ON INGREDIENTS

Formula: NdCl3

Molecular Weight: 250.6


CHEMICAL NAME                                         CAS#                          %


Neodymium (III) chloride, anhydrous                                       10024-93-8                                     100

SECTION 4   FIRST AID MEASURES

EYE EXPOSURE: Immediately flush the eyes with copious amounts of water for at least 15 minutes. Assure flushing under
eyelids. A victim may need assistance in keeping their eyelids open. Get immediate competent medical attention.
SKIN EXPOSURE: Wash affected area with soap and water. Remove contaminated clothes if necessary. Seek medical
assistance if irritation persists.
INHALATION: Remove the victim to fresh air. Closely monitor the victim for signs of respiratory problems, such as difficulty
in breathing, coughing, wheezing, or pain. In such cases, seek immediate medical assistance.
INGESTION: Seek medical assistance immediately. Keep the victim calm. Give the victim water (only if conscious). Induce
vomiting only if directed by medical personnel.

SECTION 5   FIREFIGHTING MEASURES

FLASH POINT: Product is not flammable
AUTO IGNITION TEMPERATURE: Not applicable
EXPLOSION LIMITS: Not applicable
EXTINGUISHING MEDIUM: Use fire fighting measures that suit the surrounding fire.
SPECIAL FIRE FIGHTING PROCEDURES: If involved in a fire, fire fighters should be equipped with a NIOSH approved
positive self-contained breathing apparatus, flame and chemical resistant clothing, hats, boots, and gloves.
HAZARDOUS COMBUSTION AND DECOMPOSITION PRODUCTS: Hydrogen chloride gas and neodymium oxides

SECTION 6   ACCIDENTAL RELEASE MEASURES

PERSONAL PRECAUTIONS: Wear approved personal protective equipment. Avoid dust formation. Avoid breathing dust, vapors,
mist, or gas. Ensure adequate ventilation.
ENVIRONMENTAL PRECAUTIONS: Do not let product enter drains or allow to be released into the environment.
METHODS AND MATERIALS FOR CONTAINMENT AND CLEANING UP: Small spills can be mixed with vermiculite or sodium
carbonate powder and swept up.

SECTION 7   HANDLING AND STORAGE

PRECAUTIONS FOR SAFE HANDLING: Avoid contact with skin and eyes. Avoid formation of dust. Ensure adequate ventilation.
CONDITIONS FOR SAFE STORAGE: Store material in a tightly sealed container away from moisture, in a cool, dry, and well-
ventilated area.

SECTION 8  EXPOSURE CONTROLS AND PERSONAL PROTECTION

EYE PROTECTION: Always wear approved safety glasses with side shields, safety goggles, or face shield when handling a chemical
substance in the laboratory.
SKIN PROTECTION: Chemical resistant gloves.
VENTILATION: Handle in an efficient chemical fume hood.
RESPIRATOR:  If in form of fine dust and ventilation is not available a respirator should be worn. The use of respirators requires a
Respirator Protection Program to be in compliance with 29 CFR 19-10.134.

SECTION 9 PHYSICAL AND CHEMICAL PROPERTIES

COLOR AND FORM: Color varies with different light sources
MOLECULAR WEIGHT: 250.6
BOILING POINT: 1600° C
MELTING POINT: 784° C


NEODYMIUM (III) CHLORIDE, ANHYDROUS                                                          PAGE 2
```

## Page 3

```text
SECTION 9 PHYSICAL AND CHEMICAL PROPERTIES (Cont.)

SPECIFIC GRAVITY: 4.134 gm/ml
VAPOR PRESSURE: Not applicable
SOLUBILITY: 96.7 g/100cc (13°C)

SECTION 10  STABILITY AND REACTIVITY


STABILITY: Stable
HAZARDOUS POLYMERIZATION: No hazardous polymerization
CONDITIONS TO AVOID: Moisture
INCOMPATIBILITY: Strong oxidizing agents, water, moisture, and active metals
DECOMPOSITION PRODUCTS: Hydrogen chloride gas and neodymium oxide


SECTION 11 TOXICOLOGICAL DATA


ACUTE TOXICITY: Administration onto the skin (rabbit); Standard Draize test: 500 mg/24H. Administration into the eye (rabbit);
Standar Draize test: 50 mg. Intraperitoneal (rat); LD50:150 mg/kg. Subcutaneous (rat); LDLo:150 mg/kg. Intravenous (rat); LD50:3500
ug/kg. Oral (mouse); LD50:3692 mg/kg. Intraperitoneal (guinea pig); LD50:140 mg/kg. Subcutaneous (guinea pig); LD50:243 mg/kg.
Intravenous (guinea pig); LD50:122 mg/kg. Subcutaneous (frog); LD50:434 mg/kg. unreported (mammal-species unspecified);
LDLo:40 mg/kg.
CARCINOGENIC EFFECTS: No components of this product present at levels greater than or equal to 0.1% is identified as a confirmed
carcinogen by IARC, ACGIH, NTP, and OSHA.
MUTAGENIC EFFECTS: Not available
TETRATOGENIC EFFECTS: Not available
RTECS: QO8750000

To the best of our knowledge the toxicological effects of this compound have not been fully investigated.

SECTION 12  ECOLOGICAL DATA

No information available

SECTION 13  DISPOSAL CONSIDERATIONS

Dispose of in according to local, state, and federal regulations.

SECTION 14  TRANSPORTATION DATA

Non-hazardous material


SECTION 15  REGULATORY INFORMATION

TSCA: Listed in the TSCA inventory

SARA 313 COMPONENTS: This material does not contain any chemical components with know CAS numbers that exceed the
threshold (De Minimis) reporting levels established by SARA Title III, Section 313.

SARA 302 COMPONENTS: No chemicals in this material are subject to the reporting requirements of SARA Title III, Section 302.

SARA 311/312 HAZARDS: Acute Health Hazard

MASSACHUSETTS RIGHT TO KNOW COMPONENTS: No components are subject to the Massachusetts Right To Know Act.

PENNSYLVANIA RIGHT TO KNOW COMPONENTS: Neodymium trichloride

NEW JERSEY RIGHT TO KNOW COMPONENTS: Neodymium trichloride





NEODYMIUM (III) CHLORIDE, ANHYDROUS                                                          PAGE 3
```

## Page 4

```text
SECTION 15  REGULATORY INFORMATION (Cont.)

CALIFORNIA PROP. 65 COMPONENTS: This product does not contain any chemicals known to State of California to cause cancer,
birth defects, or any other reproductive harm.


SECTION 16  OTHER INFORMATION

DISCLAIMER: The information herein is believed to be accurate and reliable as of the date compiled. However, Prochem, Inc.
makes no representation, warranty, or guarantee of any kind with respect to the information in this document or any use of the
product based on the information.
DATE PREPARED: 05/14





NEODYMIUM (III) CHLORIDE, ANHYDROUS                                                          PAGE 4
```