# Lutetium, Powder – ProChem SDS

Text extracted from the original PDF. Tables, images, symbols and OCR may differ. Check the original PDF for safety information.

- **Document title:** Lutetium, Powder – ProChem SDS
- **Publisher:** ProChem, Inc\.
- **Material:** Lutetium, Powder
- **CAS number:** 7439\-94\-3
- **Product code / grade:** 2386
- **Document type:** SDS
- **Original language:** English
- **Region:** United States
- **Revision date:** 05/15
- **Page count:** 4
- **Original filename:** prochem\-lutetiumpowder40mesh\-2386\.pdf
- **RESDS page:** https://resds\.com/document/lutetium\-powder\-prochem\-en\-703aff52d1
- **Original PDF:** https://resds\.com/pdf/lutetium\-powder\-prochem\-en\-703aff52d1\.pdf
- **Source URL:** https://prochemonline\.com/wp\-content/uploads/2021/06/2386\.LutetiumPowder\.pdf
- **Description:** Collected by RESDS\. Original publisher PDF retained\. Original ProChem SDS for Lutetium, Powder\. Product number 2386; revision 05/15\. Publication authorized by the user on 2026\-09\-14\.

## Page 1

```text
 SECTION 1     PRODUCT AND COMPANY INFORMATION

 PRODUCT NAME:    Lutetium, Powder

 PRODUCT NUMBER:  2386

 CAS NUMBER:        7439-94-3

 MANUFACTURER:


 Prochem, Inc.                                         PHONE:        815-398-1788
 826 Roosevelt Road                                          FAX:           815-398-1810
 Rockford, IL  61109                                     TOLL FREE:    800-795-8788

                    IN CASE OF TRANSPORTATION EMERGENCY CONTACT CHEM-TREC: 1-800-424-9300

SECTION 2    HAZARDS IDENTIFICATION

 CLASSIFICATION OF SUBSTANCE OR MIXTURE

 Pictogram


 Signal Word         Danger

 Hazard Statements

 H228               Flammable solid.
 H260                    In contact with water releases flammable gases which may ignite spontaneously.

 Precautionary Phrases

 P210              Keep away from heat/sparks/open flames/hot surfaces.
 P231+P232          Handle under inert gas. Protect from moisture.
 P280              Wear protective gloves/protective clothing/eye protection/face protection.
 P370+P378             In case of fire: Use dry sand, dry chemical or alcohol-resistant foam for extinction.
 P402+P404           Store in a dry place. Store in a closed container.

 HMIS CLASSIFICATION:
 Health: 1              Fire: 3                  Reactivity Hazard: 2
 NFPA RATING:
 Health: 1            Flammability: 3         Reactivity Hazard: 2       Specific Hazard:

 EYE CONTACT: May cause slight to mild irritation of the eyes.
 SKIN CONTACT: May cause slight to mild irritation of the skin.
 INHALATION: May be irritating to the nasal cavity, mucous membranes, and respiratory tract.
 INGESTION: No specific data available.





LUTETIUM POWDER                                                                    PAGE 1
```

## Page 2

```text
SECTION 3      COMPOSITION / INFORMATION ON INGREDIENTS

 Formula: Lu

 Molecular Weight: 174.97


 CHEMICAL NAME                                           CAS#                               %


 Lutetium                                                                7439-94-3                                              100

SECTION 4   FIRST AID MEASURES

 EYE EXPOSURE: Immediately flush the eyes with copious amounts of water for at least 15 minutes. Assure flushing under
 eyelids. A victim may need assistance in keeping their eyelids open. Get immediate competent medical attention.
 SKIN EXPOSURE: Wash affected area with water. Remove contaminated clothes if necessary. Seek medical assistance if
 irritation persists.
 INHALATION: Remove to fresh air and keep at rest.  If breathing is difficult, give oxygen.  If not breathing, give artificial
 respiration. Get medical attention.
 INGESTION: Seek medical assistance immediately. Keep the victim calm. Give the victim water (only if conscious). Induce
 vomiting only if directed by medical personnel.

SECTION 5   FIREFIGHTING MEASURES

 FLASH POINT: Not available
 AUTO IGNITION TEMPERATURE: Not available
 EXPLOSION LIMITS: Dust may form explosive mixtures with air.
 EXTINGUISHING MEDIUM: Special powder for metal fires. Do NOT use water. Contact with water liberate extremely flammable
 gases.
 SPECIAL FIRE FIGHTING PROCEDURES: Wear self-contained, approved breathing apparatus and full protective clothing,
 including eye protection and boots. Flammable solid. Burns with intense heat.
 HAZARDOUS COMBUSTION AND DECOMPOSITION PRODUCTS: Lutetium oxide and carbonate

SECTION 6   ACCIDENTAL RELEASE MEASURES

 PERSONAL PRECAUTIONS: Wear all appropriate equipment when using this material. Ensure adequate ventilation. Avoid the
 formation of dust. Avoid breathing vapors, mist, gas, or dust. Keep away from ignition sources
 ENVIRONMENTAL PRECAUTIONS: Prevent spillage from entering drains or allowing to be released into the environment.
 METHODS AND MATERIALS FOR CONTAINMENT AND CLEANING UP: Cover spill with sodium carbonate or dolomite. Sweep up
 and place in suitable container for proper disposal.

SECTION 7   HANDLING AND STORAGE

 PRECAUTIONS FOR SAFE HANDLING: Wear appropriate personal protective equipment. Avoid contact with skin and eyes. Use with
 adequate ventilation. Avoid formation of dusts and aerosols. Handle under dry protective gas. Protect against electrostatic charge.
 CONDITIONS FOR SAFE STORAGE: Store in cool, dry, and well-ventilated area. Store away from oxidizing agents, water, moisture,
 halogens, acid chlorides, and acids.  Store under dry inert gas. This product is moisture and air sensitive – protect from humidity and
 water.

SECTION 8  EXPOSURE CONTROLS AND PERSONAL PROTECTION

 EXPOSURE CONTROLS: Contains no substances with occupational exposure limit values.
 EYE PROTECTION: Wear chemical safety glasses or goggles and face shield.
 SKIN PROTECTION: Wear nitrile or rubber gloves, and a complete suit protecting against chemicals.
 VENTILATION: Provide local exhaust, preferably mechanical.
 RESPIRATOR: Use an approved respirator.
 ADDITIONAL PROTECTION: Provide eyewash stations, quick-drench showers and washing facilities accessible to areas of use and
 handling.





LUTETIUM POWDER                                                                    PAGE 2
```

## Page 3

```text
SECTION 9 PHYSICAL AND CHEMICAL PROPERTIES

 COLOR AND FORM: Silver to gray powder
 ODOR: None
 MOLECULAR WEIGHT: 174.97
 BOILING POINT: 3327°C
 MELTING POINT: 1663°C
 SPECIFIC GRAVITY: 9.842 gm/ml
 VAPOR DENSITY: No data available
 SOLUBILITY: Insoluble

SECTION 10  STABILITY AND REACTIVITY

 STABILITY: Contact with water releases flammable gases that may ignite spontaneously
 HAZARDOUS POLYMERIZATION: Reacts with strong oxidizing agents. Contact with water releases flammable gases.
 CONDITIONS TO AVOID: Contact with hot water. Mixtures of fine dust with air.
 INCOMPATIBILITY: Acids, water, alcohols, oxidizing agents, oxygen, halocarbons, mineral acids, and air.
 DECOMPOSITION PRODUCTS: Lutetium oxide and carbonate

SECTION 11 TOXICOLOGICAL DATA

 ACUTE TOXICITY: Not available
 CARCINOGENIC EFFECTS: No components of this product present at levels greater than or equal to 0.1% is identified a carcinogen.
 MUTAGENIC EFFECTS: Not available
 TETRATOGENIC EFFECTS: Not available
 CHRONIC TOXICITY: Not available
 RTECS: No data

 To the best of our knowledge the toxicological effects of this compound have not been fully investigated.

SECTION 12  ECOLOGICAL DATA


 No information available

SECTION 13  DISPOSAL CONSIDERATIONS

 Dispose of in according to local, state, and federal regulations.

SECTION 14  TRANSPORTATION DATA

 DOT:   UN3089                                      IATA:  UN3089

         Metal powders, flammable, n.o.s.                           Metal powder, flammable, n.o.s.

          (lLutetium)                                                       (lLutetium)

       CLASS 4.1                                    CLASS 4.1

      PG II                                    PG II




 Marine Pollutant: No


SECTION 15  REGULATORY INFORMATION

 TSCA: Listed in the TSCA inventory

 SARA 302/304: Not Listed




LUTETIUM POWDER                                                                    PAGE 3
```

## Page 4

```text
SECTION 15  REGULATORY INFORMATION (Cont.)

 SARA 311/312: Not Listed

 SARA (TITLE 313): Not Listed

 CALIFORNIA PROP. 65: Not Listed

 MASSACHUSETTS RIGHT TO KNOW COMPONENTS: No components are subject to the Massachusetts Right to Know Act.

 NEW JERSEY RIGHT TO KNOW COMPONENTS: No components are subject to the New Jersey Right to Know Act.

 PENNSYLVANIA RIGHT TO KNOW COMPONENTS: No components are subject to the Pennsylvania Right to Know Act.


SECTION 16  OTHER INFORMATION

 DISCLAIMER: The information herein is believed to be accurate and reliable as of the date compiled. However, Prochem, Inc.
 makes no representation, warranty, or guarantee of any kind with respect to the information in this document or any use of the
 product based on the information.
 DATE PREPARED: 05/15
 SDS DEPT.





LUTETIUM POWDER                                                                    PAGE 4
```