Europium (Eu) Metal — Safety Data Sheet (SDS) PAGE 1 SDS Safety Data Sheet per 29 CFR 1910.1200 Page 1 of 4 Europium SAFETY DATA SHEET 1 PRODUCT AND SUPPLIER IDENTIFICATION Product Name: Europium - pieces, ingot, sheet, foil, rod Formula: Eu Supplier: Ames Laboratory, US DOE Materials Preparation Center 121 Metals Development Ames, IA 50010 USA Telephone: 515-294-5236 Fax: 515-294-8727 Email: mpc@ameslab.gov Emergency: 515-294-3483 (24 hour) Recommended Uses: Scientific Research 2 HAZARDS IDENTIFICATION GHS Classification (29 CFR 1910.1200): Water reactive solid, flammable. GHS Label Elements: Signal Word: Danger Hazard Statements: H228 Flammable solid, H261 In contact with water releases flammable gas. Precautionary Statements: P210 Keep away from heat/sparks/open flames/hot surfaces - No smoking, P223 Do not allow contact with water, P231+P232 Handle under inert gas. Protect from moisture, P370+P378 In case of fire: Use Class D dry chemical extinguishing agent for extinction, P422 Store contents under inert gas. 3 COMPOSITION/INFORMATION ON INGREDIENTS Ingredient: Europium CAS#: 7440-53-1 %: 100 EC#: 231-161-7 4 FIRST AID MEASURES INHALATION: Remove to fresh air, keep warm and quiet, give oxygen if breathing is difficult. Seek medical attention. INGESTION: Quickly wipe material from mouth and rinse with water. Do not induce vomiting. Seek medical attention. SKIN: Remove contaminated clothing, brush material off skin, wash affected area with soap and water. Seek medical attention if symptoms persist. EYES: Flush eyes with lukewarm water, including under upper and lower eyelids, for at least 15 minutes. Seek medical attention if symptoms persist. Most Important Symptoms/Effects, Acute and Delayed: May cause irritation. See section 11 for more information. Indication of Immediate Medical Attention and Special Treatment: No other relevant information available. 5 FIREFIGHTING MEASURES Extinguishing Media: Use Class D dry powder extinguishing agent. Unsuitable Extinguishing Media: Do not use water. Ames Laboratory is operated for the U.S. DOE by Iowa State University, DE-AC02-07CH11358 Page 1 of 4 PAGE 2 SDS Safety Data Sheet per 29 CFR 1910.1200 Page 2 of 4 Specific Hazards Arising from the Material: Flammable when exposed to heat, spark or flame. Will react with water liberating hydrogen gas and europium hydroxide. May emit fumes of europium oxide under fire conditions. Special Protective Equipment and Precautions for Firefighters: Full face, self-contained breathing apparatus and full protective clothing to prevent contact with skin and eyes. 6 ACCIDENTAL RELEASE MEASURES Personal Precautions, Protective Equipment, and Emergency Procedures: Wear appropriate respiratory and protective equipment specified in section 8. Avoid contact with skin and eyes. Avoid breathing dust or fume. Eliminate all sources of ignition. Isolate spill area. Methods and Materials for Containment and Cleaning Up: Sweep or scoop spilled product and place in a closed container for further handling and disposal. Do not use water for spill clean-up. Use only non-sparking tools and natural bristle brushes. Environmental Precautions: Do not flush to sewer, stream, or other bodies of water. Do not allow to enter drains or to be released to the environment. 7 HANDLING AND STORAGE Precautions for Safe Handling: Europium is extremely reactive to oxygen and water/moisture. Handle in an enclosed, controlled process. Handle under dry protective gas such as argon. Use non-sparking tools. Protect from sources of ignition. Do not allow contact with water. Avoid contact with skin and eyes. Wash thoroughly before eating or smoking. See section 8 for information on personal protection equipment. Conditions for Safe Storage, Including Any Incompatibilities: Europium metal should be stored in tightly-closed containers under argon or mineral oil. Keep away from sparks, heat and flame. Storage area should be free of combustibles and ignition sources. Protect from water/moisture. Do not store together with acids or oxidizers. See section 10 for more information on incompatible materials. 8 EXPOSURE CONTROLS AND PERSONAL PROTECTION Exposure Limits: Europium OSHA/PEL: No exposure limit established ACGIH/TLV: No exposure limit established Appropriate Engineering Controls: Handle in a humidity controlled atmosphere. Handle in an enclosed, controlled process under dry argon. Use local exhaust to maintain exposure at low levels. Whenever possible the use of local exhaust ventilation or other engineering controls is the preferred method of controlling exposure to airborne dust and fume to meet established occupational exposure limits. Do not use tobacco or food in work area. Wash thoroughly before eating or smoking. Do not blow dust off clothing or skin with compressed air. Prepare for the possibility of a fire. Keep extinguishing agents, tools for handling and protective clothing readily available. Individual Protection Measures, Such as Personal Protective Equipment: Respiratory Protection: Wear a NIOSH/MSHA approved respirator when high concentrations are present. Eye Protection: Always wear approved chemical splash proof goggles. Skin Protection: Rubber gloves, flame retardant protective work clothing. 9 PHYSICAL AND CHEMICAL PROPERTIES Appearance: Form: Solid in various forms Color: Gray metallic Odor: Not determined Odor Threshold: Not determined pH: N/A Melting Point: 822 oC Boiling Point: 1527 oC Flash Point: N/A Evaporation Rate: N/A Flammability: Flammable solid Upper Flammable Limit: No data Lower Flammable Limit: No data Vapor Pressure: No data Vapor Density: N/A Relative Density (Specific Gravity): 5.25 g/cc Solubility in H2O: Decomposes Ames Laboratory is operated for the U.S. DOE by Iowa State University, DE-AC02-07CH11358 Page 2 of 4 PAGE 3 SDS Safety Data Sheet per 29 CFR 1910.1200 Page 3 of 4 Partition Coefficient (n-octanol/water): Not determined Autoignition Temperature: No data Decomposition Temperature: No data Viscosity: N/A 10 STABILITY AND REACTIVITY Reactivity: No data Chemical Stability: Stable under recommended storage conditions. Possibility of Hazardous Reactions: Finely divided metal may ignite spontaneously in air. Reacts with water releasing flammable hydrogen gas. Incompatible Materials: Water/moisture, air, strong acids, acid chlorides, strong oxidizing agents, halogens. Hazardous Decomposition Products: Europium oxides, hydrogen gas. 11 TOXICOLOGICAL INFORMATION Likely Routes of Exposure: Inhalation, skin and eyes. Symptoms of Exposure: May cause irritation. Acute and Chronic Effects: No data Acute Toxicity: No data Carcinogenicity: NTP: Not identified as carcinogenic IARC: Not identified as carcinogenic To the best of our knowledge the chemical, physical and toxicological characteristics of the substance are not fully known. 12 ECOLOGICAL INFORMATION Ecotoxicity: No data Persistence and Degradability: No data Bioaccumulative Potential: No data Mobility in Soil: No data Other Adverse Effects: Do not allow material to be released to the environment. No further relevant information available. 13 DISPOSAL CONSIDERATIONS Waste Disposal Method: Product: Dispose of in accordance with Federal, State and Local regulations. Packaging: Dispose of in accordance with Federal, State and Local regulations. 14 TRANSPORT INFORMATION DOT/ADR/IATA/IMDG Regulations: UN Number: UN3132 UN Proper Shipping Name: Water reactive solid, flammable, n.o.s. (Europium) Transport Hazard Class: 4.3, 4.1 Packing Group: III Marine Pollutant: No Special Precautions: Warning: flammable solid. releases flammable gas in contact with water. 15 REGULATORY INFORMATION TSCA Listed: All components are listed. Regulation (EC) No 1272/2008 (CLP): Flammable solid, category 1; Substances which, in contact with water, emit flammable gases, category 1. Canada WHMIS Classification (CPR, SOR/88-66): Class B, Division 4 - Flammable solid; Class B, Division 6 - Reactive flammable material. HMIS Ratings: Health: 1 Flammability: 3 Physical: 2 NFPA Ratings: Health: 1 Flammability: 3 Reactivity: 2 Special Hazard: W Chemical Safety Assessment: A chemical safety assessment has not been carried out. 16 OTHER INFORMATION Ames Laboratory is operated for the U.S. DOE by Iowa State University, DE-AC02-07CH11358 Page 3 of 4 PAGE 4 SDS Safety Data Sheet per 29 CFR 1910.1200 Page 4 of 4 The above information is believed to be correct, but does not purport to be all inclusive and shall be used only as a guide. The Materials Preparation Center, Ames Laboratory, and Iowa State University, shall not be held liable for any damages resulting from handling or from contact with the above product and make no warranties, expressed or implied, including, but not limited to, any implied warranty of merchantability or fitness for a particular purpose or course of performance or usage of trade. Prepared by: The Materials Preparation Center at Ames Laboratory Revised/Reviewed: March 23, 2018 Ames Laboratory is operated for the U.S. DOE by Iowa State University, DE-AC02-07CH11358 Page 4 of 4