# Scandium, lump, vacuum remelted SDS – ProChem, Inc\.

原本PDFから抽出したテキストです。表、画像、記号、OCR結果は原本と異なる場合があります。安全情報は原本PDFで確認してください。

- **文書名:** Scandium, lump, vacuum remelted SDS – ProChem, Inc\.
- **発行元:** ProChem, Inc\.
- **材料:** Scandium, lump, vacuum remelted
- **CAS番号:** 7440\-20\-2
- **製品番号・グレード:** 3112
- **文書種類:** SDS
- **原文の言語:** English
- **地域:** United States
- **改訂日:** 08/14
- **ページ数:** 3
- **原本ファイル名:** prochem\-3112\.ScandiumLumpVacuumRemelted\.pdf
- **RESDSページ:** https://resds\.com/document/scandium\-lump\-vacuum\-remelted\-sds\-prochem\-en\-9aa8818054
- **原本PDF:** https://resds\.com/pdf/scandium\-lump\-vacuum\-remelted\-sds\-prochem\-en\-9aa8818054\.pdf
- **情報源URL:** https://prochemonline\.com/wp\-content/uploads/2021/06/3112\.ScandiumLumpVacuumRemelted\.pdf
- **説明:** Collected by RESDS\. Original publisher PDF retained\. Original manufacturer safety data sheet for Scandium, lump, vacuum remelted\. Product number: 3112\. Original revision: 08/14\. Published under the file\-level authorization confirmed by the user for the frozen 1,125\-file manifest\.

## ページ 1

```text
 SECTION 1     PRODUCT AND COMPANY INFORMATION

 PRODUCT NAME:    Scandium, lump, vacuum remelted

 PRODUCT NUMBER:  3112

 CAS NUMBER:        7440-20-2

 MANUFACTURER:


 Prochem, Inc.                                         PHONE:        815-398-1788
 826 Roosevelt Road                                          FAX:           815-398-1810
 Rockford, IL  61109                                     TOLL FREE:    800-795-8788

                    IN CASE OF TRANSPORTATION EMERGENCY CONTACT CHEM-TREC: 1-800-424-9300

SECTION 2    HAZARDS IDENTIFICATION

 CLASSIFICATION OF SUBSTANCE OR MIXTURE

 Not a dangerous substance according to GHS.

 HMIS CLASSIFICATION:
 Health: 0              Fire: 0                  Reactivity Hazard: 0       Personal: A
 NFPA RATING:
 Health: 0            Flammability: 0         Reactivity Hazard: 0       Specific Hazard:

 EYE CONTACT: May cause slight to mild irritation of the eyes.
 SKIN CONTACT: May cause slight to mild irritation of the eyes.
 INHALATION: May cause respiratory tract irritation.
 INGESTION: May be harmful if swallowed


SECTION 3      COMPOSITION / INFORMATION ON INGREDIENTS

 Formula: Sc

 Molecular Weight: 44.96


 CHEMICAL NAME                                           CAS#                               %


 Scandium                                                               7440-20-2                                              100

SECTION 4   FIRST AID MEASURES

 EYE EXPOSURE: Immediately flush the eyes with copious amounts of water for at least 15 minutes. Assure flushing under
 eyelids. A victim may need assistance in keeping their eyelids open. Get immediate competent medical attention.
 SKIN EXPOSURE: Wash affected area with water. Remove contaminated clothes if necessary. Seek medical assistance if
 irritation persists.
 INHALATION: Remove to fresh air and keep at rest.  If breathing is difficult, give oxygen.  If not breathing, give artificial
 respiration. Get medical attention if necessary.



SCANDIUM, LUMP, VACUUM REMELTED                                                      PAGE 1
```

## ページ 2

```text
SECTION 4   FIRST AID MEASURES (Cont.)

 INGESTION: Do NOT induce vomiting. Never give anything by mouth to an unconscious person.  If conscious, wash out mouth
 with water. Get medical attention if necessary.

SECTION 5   FIREFIGHTING MEASURES

 FLASH POINT: Not available
 AUTO IGNITION TEMPERATURE: Not available
 EXPLOSION LIMITS: Not available
 EXTINGUISHING MEDIUM: Halogenated extinguisher and water.
 SPECIAL FIRE FIGHTING PROCEDURES: Wear self-contained, approved breathing apparatus and full protective clothing,
 including eye protection and boots.
 HAZARDOUS COMBUSTION AND DECOMPOSITION PRODUCTS: Scandium oxides

SECTION 6   ACCIDENTAL RELEASE MEASURES

 PERSONAL PRECAUTIONS: Wear all appropriate equipment when using this material. Ensure adequate ventilation. Avoid the
 formation of dust. Avoid breathing vapors, mist, gas, or dust.
 ENVIRONMENTAL PRECAUTIONS: Prevent spillage from entering drains or allowing to be released into the environment.
 METHODS AND MATERIALS FOR CONTAINMENT AND CLEANING UP: Pick up and place in suitable container for proper disposal.

SECTION 7   HANDLING AND STORAGE

 PRECAUTIONS FOR SAFE HANDLING: Wear appropriate personal protective equipment. Avoid contact with skin and eyes. Use with
 adequate ventilation. Wash thoroughly after using. Keep container closed when not in use. Avoid formation of dusts and aerosols.
 Handle under dry protective gas.
 CONDITIONS FOR SAFE STORAGE: Store in cool, dry, and well-ventilated area. Store away from halogens, oxidizing agents, air,
 water, and moisture.

SECTION 8  EXPOSURE CONTROLS AND PERSONAL PROTECTION

 EXPOSURE CONTROLS: Contains no substances with occupational exposure limit values.
 EYE PROTECTION: Wear chemical safety glasses or goggles and face shield.
 SKIN PROTECTION: Wear nitrile or rubber gloves, and a complete suit protecting against chemicals.
 VENTILATION: Provide local exhaust, preferably mechanical.
 RESPIRATOR: Use an approved respirator.
 ADDITIONAL PROTECTION: Provide eyewash stations, quick-drench showers and washing facilities accessible to areas of use and
 handling.

SECTION 9 PHYSICAL AND CHEMICAL PROPERTIES


 COLOR AND FORM: Gray lumps
 ODOR: None
 MOLECULAR WEIGHT: 44.96
 BOILING POINT: 2730°C
 MELTING POINT: 1540°C
 SPECIFIC GRAVITY: 2.99 gm/ml
 VAPOR DENSITY: No data available
 SOLUBILITY: Insoluble

SECTION 10  STABILITY AND REACTIVITY


 STABILITY: Stable
 HAZARDOUS POLYMERIZATION: Will not occur
 CONDITIONS TO AVOID: Contact with water
 INCOMPATIBILITY: Water, alcohols, oxidizers, oxygen, halogens, halocarbons, and mineral acids.
 DECOMPOSITION PRODUCTS: Scandium Oxide




SCANDIUM, LUMP, VACUUM REMELTED                                                      PAGE 2
```

## ページ 3

```text
SECTION 11 TOXICOLOGICAL DATA


 ACUTE TOXICITY: Not available
 CARCINOGENIC EFFECTS: No components of this product present at levels greater than or equal to 0.1% is identified a carcinogen.
 MUTAGENIC EFFECTS: Not available
 TETRATOGENIC EFFECTS: Not available
 CHRONIC TOXICITY: Scandium has a low order of toxicity. As with calcium, the toxicity is generally a function of the anion.

 To the best of our knowledge the toxicological effects of this compound have not been fully investigated.

SECTION 12  ECOLOGICAL DATA

 No data available.

SECTION 13  DISPOSAL CONSIDERATIONS


 Dispose of in according to local, state, and federal regulations.

SECTION 14  TRANSPORTATION DATA

 Not a dangerous good.


SECTION 15  REGULATORY INFORMATION

 TSCA: Listed in the TSCA inventory

 DSCL (EEC): Listed on the DSCL inventory

 SARA 302/304: Not Listed

 SARA 311/312: No SARA Hazard

 SARA (TITLE 313): Not Listed

 CALIFORNIA PROP. 65: Not Listed

 WHMIS CANADA: Not Listed

 NEW JERSEY RIGHT TO KNOW COMPONENTS: Scandium

 PENNSYLVANIA RIGHT TO KNOW COMPONENTS: Scandium


SECTION 16  OTHER INFORMATION

 DISCLAIMER: The information herein is believed to be accurate and reliable as of the date compiled. However, Prochem, Inc.
 makes no representation, warranty, or guarantee of any kind with respect to the information in this document or any use of the
 product based on the information.
 DATE PREPARED: 08/14





SCANDIUM, LUMP, VACUUM REMELTED                                                      PAGE 3
```