ツリウム (III) acetate hydrate 3589 SDS
RESDSが収集し、発行元の原本PDFをそのまま保持しています。 Original ProChem SDS for Thulium (III) acetate hydrate. Product number 3589; revision 06/22. Publication authorized by the user on 2026-09-14.
PDFプレビュー
無料で閲覧・ダウンロード可能・登録やログインは不要です。
PDFを読み込み中…
Normalized SDS data & document analysis
RESDS derives the results below from this document’s extracted text and the site’s same-material index. Detected codes are not reclassified. “Not detected” does not mean “not present”; confirm the original PDF for safety-critical use.
GHS & transport evidence
ページ links show the first occurrence found in extracted text.
SDS 16-section coverage
14 section headings detected; 2 not detected by the parser.
Same-material SDS comparison
2 indexed 件の文書 · 2 publishers · 1 languages · 2 stated revisions · page range 3–8. This compares document metadata, not product equivalence.
| 発行元 | 改訂版 | 言語 | 国・地域 | ページ数 |
|---|---|---|---|---|
| Current ProChem, Inc. | 06/22 | 英語 | 米国 | 3 |
| Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific) | 31-Jul-2026 | 英語 | 英国 | 8 |
材料・文書仕様
- Material
- Thulium (III) acetate hydrate
- 製品・グレード
- 3589
- 発行元
- ProChem, Inc.
- 国・地域
- 米国
- ファイル名
- prochem-thulium-acetate-3589.pdf
- 文書の種類
- SDS
- CAS登録番号
- 314041-04-8
- 言語
- 英語
- 原本改訂日
- 06/22
- ページ数
- 3
- ファイルサイズ
- 890 KB
- ダウンロード数
- 4
- 追加日
- 2026-09-14
この文書が該当する理由
組成が完全に確認されていない場合があります。記載のない元素が含まれていないとは限りません。
Thulium (III) acetate hydrate 314041-04-8 100
その他の記載元素: C, H, O
Full document text
3ページ · 原文書の言語
Text extracted from the original PDF. ページ order and original wording are preserved; tables and symbols may differ from the PDF layout. Check the original PDF for safety-critical details.
ページ 1
SECTION 1 PRODUCT AND COMPANY INFORMATION
PRODUCT NAME: Thulium (III) acetate hydrate
PRODUCT NUMBER: 3589
CAS NUMBER: 314041-04-8
MANUFACTURER:
ProChem, Inc. PHONE: 815-398-1788 826 Roosevelt Road FAX: 815-398-1810 Rockford, IL 61109 TOLL FREE: 800-795-8788
IN CASE OF TRANSPORTATION EMERGENCY CONTACT CHEM-TREC: 1-800-424-9300
SECTION 2 HAZARDS IDENTIFICATION
CLASSIFICATION OF SUBSTANCE OR MIXTURE
Pictogram
Signal Word Warning
Hazard Statements
H315 Causes skin irritation. H319 Causes serious eye irritation. H335 May cause respiratory irritation.
Precautionary Phrases
P261 Avoid breathing dust/fume/gas/mist/vapors/spray. P264 Wash face, hands, and any exposed skin thoroughly after handling. P271 Use only outdoors or in a well-ventilated area. P280 Wear protective gloves/protective clothing/eye protection/face protection. P302 + P352 IF ON SKIN: Wash with plenty of soap and water. P304 + P340 + P312 IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. Call a POISON CENTER or doctor/physician if you feel unwell. P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P403 + P233 Store in a well-ventilated place. Keep container tightly closed.
THULIUM (III) ACETATE PAGE 1
ページ 2
SECTION 2 HAZARDS IDENTIFICATION (Cont.)
EYE CONTACT: Causes serious eye irritation. SKIN CONTACT: Causes skin irritation. INHALATION: May be irritation to the nose, mucous membranes, and respiratory tract. INGESTION: May cause respiratory irritation.
SECTION 3 COMPOSITION / INFORMATION ON INGREDIENTS
Formula: Tm(OOCCH3)3 · XH2O
Molecular Weight: 346.07 (anhy)
CHEMICAL NAME CAS# %
Thulium (III) acetate hydrate 314041-04-8 100
SECTION 4 FIRST AID MEASURES
EYE EXPOSURE: Check for and remove contact lenses. In case of contact, immediately flush eyes with plenty of water for at least 15 minutes. Get medical attention. SKIN EXPOSURE: In case of contact, immediately flush skin with plenty of water. If skin irritation persists, call a physician. INHALATION: Remove to fresh air. If not breathing, give artificial respiration. Get medical attention. INGESTION: Clean out mouth with water. Drink plenty of water afterwards. Get medical attention if symptoms occur.
SECTION 5 FIREFIGHTING MEASURES
FLASH POINT: Not applicable AUTO IGNITION TEMPERATURE: Not applicable EXPLOSION LIMITS: None EXTINGUISHING MEDIUM: Carbon dioxide, powder, water spray. In case of major fire and large quantities: Evacuate area. Fight fire remotely due to the risk of explosion. SPECIAL FIRE FIGHTING PROCEDURES: Keep product and empty container away from heat and sources of ignition. HAZARDOUS COMBUSTION AND DECOMPOSITION PRODUCTS: Carbon monoxide, carbon dioxide, and metal oxides.
SECTION 6 ACCIDENTAL RELEASE MEASURES
PERSONAL PRECAUTIONS: Always wear appropriate protective equipment. Ensure adequate ventilation. Avoid dust formation. ENVIRONMENTAL PRECAUTIONS: 情報なし METHODS AND 材料名S FOR CONTAINMENT AND CLEANING UP: Sweep up and shovel into suitable containers for proper disposal.
SECTION 7 HANDLING AND STORAGE
PRECAUTIONS FOR SAFE HANDLING: Do not breathe dust. Wear suitable protective clothing. Avoid dust formation. CONDITIONS FOR SAFE STORAGE: Store under an inert atmosphere. Keep container tightly closed in a dry and well-ventilated area. Protect from moisture.
SECTION 8 EXPOSURE CONTROLS AND PERSONAL PROTECTION
EYE PROTECTION: Always wear approved safety glasses w/side shields, or safety goggles, face shield when handling a chemical substance in the laboratory. SKIN PROTECTION: Chemical-resistant gloves. VENTILATION: Use process enclosures, local exhaust ventilation, or other engineering controls to keep airborne levels below recommended exposure limits. If user operations generate dust, fume or mist, use ventilation to keep exposure to airborne contaminants below the exposure limit. RESPIRATOR: If in form of fine dust and ventilation is not available a respirator should be worn. The use of respirators requires a Respirator Protection Program to be in compliance with 29 CFR 19-10.134.
THULIUM (III) ACETATE PAGE 2
ページ 3
SECTION 9 PHYSICAL AND CHEMICAL PROPERTIES
COLOR AND FORM: Off-white solid MOLECULAR WEIGHT: 346.07 (anhy) MELTING POINT: No data available SPECIFIC GRAVITY: No data available BOILING POINT: No data available VAPOR PRESSURE: No data available SOLUBILITY IN WATER: No data available
SECTION 10 STABILITY AND REACTIVITY
STABILITY: Stable HAZARDOUS POLYMERIZATION: Will not occur CONDITIONS TO AVOID: Exposure to moisture and water. INCOMPATIBILITY: Oxidizing agents DECOMPOSITION PRODUCTS: Carbon monoxide, carbon dioxide, and metal oxides.
SECTION 11 TOXICOLOGICAL DATA
CARCINOGENIC EFFECTS: No component of this product presents at levels ≥ 0.1% is identified as probable, possible or confirmed carcinogen by IARC. MUTAGENIC EFFECTS: 情報なし TETRATOGENIC EFFECTS: 情報なし DEVELOPMENTAL TOXICITY: 情報なし
To the best of our knowledge the toxicological effects of this compound have not been fully investigated.
SECTION 12 ECOLOGICAL DATA
No information available
SECTION 13 DISPOSAL CONSIDERATIONS
Dispose of in according to local state and federal regulations.
SECTION 14 TRANSPORTATION DATA
Non-hazardous
SECTION 15 REGULATORY INFORMATION
TSCA: Not listed in the TSCA inventory CALIFORNIA PROP 65: The product does not contain any Proposition 65 chemicals.
SECTION 16 OTHER INFORMATION
DISCLAIMER: The information herein is believed to be accurate and reliable as of the date compiled. However, Prochem, Inc. makes no representation, warranty, or guarantee of any kind with respect to the information in this document or any use of the product based on the information. DATE PREPARED: 06/22 SDS DEPT.
THULIUM (III) ACETATE PAGE 3
同一材料:他の発行元によるSDS
1 件の文書がこの材料索引にあります。製品グレード、水和状態、配合は各原本PDFで確認してください。
原発行元・企業情報
ProChem, Inc.
- ブランド・組織
- ProChem
- 国・地域/事業所
- 米国
- ウェブサイト
- prochemonline.com
- SDS記載の連絡先メール
- 記載なし in SDS
- SDS記載の電話番号
- 815-398-1788
- 製品・参照番号
- 3589
Official site identifies ProChem, Inc. at 826 Roosevelt Road, Rockford, IL 61109 and publishes its general contact email.
抽出した供給元情報を表示
COMPANY INFORMATION PRODUCT NAME: Thulium (III) acetate hydrate PRODUCT NUMBER: 3589 CAS NUMBER: 314041-04-8 MANUFACTURER: ProChem, Inc. PHONE: 815-398-1788 826 Roosevelt Road FAX: 815-398-1810 Rockford, IL 61109 TOLL FREE: 800-795-8788
RESDSについて ProChem, Inc.
Official site identifies ProChem, Inc. at 826 Roosevelt Road, Rockford, IL 61109 and publishes its general contact email.
Company website & profile文書の出典・収録履歴
原登録: Thulium (III) acetate hydrate – ProChem SDS
追加日: 2026-09-14T07:50:41.000Z · 登録更新: 2026-09-14T09:37:05.650Z
原本ファイル SHA-256: 5844d2ebf85ec290a8423e56a23d7ee93d516cbeeac48a72ab952fbcd6840bf5
原典PDF訂正・文書更新を依頼
メタデータの誤り、抽出エラー、供給元による新版、権利上の問題を報告できます。報告内容は運営者が確認するため非公開で保存され、送信しただけで公開中のSDSが直ちに変更されることはありません。
報告内容と任意のメールアドレスは、対応のため非公開で保存されます。サイト上には公開されません。機密情報や個人の重要情報を入力しないでください。
公式化学物質情報源
情報源ガイド ↗このSDSに記載されたCAS番号です。以下の性質は個々の物質に関するもので、製品全体を示すとは限りません。混合物、グレード、水和状態については原本SDSをご確認ください。
CAS 314041-04-8化学物質の参考情報・情報源リンク
CAS 314041-04-8 · CAS Common Chemistry ↗ · PubChem ↗
- 化学物質名(IUPAC)
- PubChemで確認 ↗
- 分子式
- PubChemで確認 ↗
- 分子量
- PubChemで確認 ↗
- 主な別名
- PubChemで確認 ↗
- 化学構造
- PubChemで構造を表示 ↗
この参考リンクを開くと、PubChemで公開されている物性情報を取得できます。公式検索リンクは引き続き利用できます。
ECHA CHEM · CAS番号を検索 314041-04-8 ↗ · AICISインベントリ · CAS番号を検索 314041-04-8 ↗
GHSは分類基準を示すものです。適用される危険有害性分類は、対象製品および各法域について個別に確認してください。
この材料の供給元
該当材料のSDSと公式製品ページから確認した企業です。グレード、組成、供給状況は供給元へ直接ご確認ください。確認できない連絡先は推測して掲載しません。
| Company | 国・地域 | ウェブサイト | メール | 電話番号 | Evidence |
|---|---|---|---|---|---|
| Avocado Research Chemicals Ltd. | 英国 | ウェブサイト | 記載なし | +44 (0) 1524 850506 | 情報源 Same material SDS; verify grade and availability |
ウェブでその他の供給元を検索
この材料を複数の検索エンジンで検索
検索語: Thulium (III) acetate hydrate SDS
Wikipediaによる材料の基礎情報
Wikipediaで Thulium (III) acetate hydrate を検索します。該当記事がある場合は概要を表示します。製品固有の混合物や標準物質には専用記事がない場合があります。
Wikipediaでこの材料を検索 ↗Wikipedia執筆者による概要: CC BY-SA 4.0. 一般的な材料情報であり、対象製品のSDSに代わるものではありません。