Neodymium metal SDS
Neodymium (Nd) elemental rare earth metal SDS, CAS 7440-00-8, published by Ames Laboratory. Original supplier PDF for the stated solid forms; revision January 26, 2016.
Free SDS PDF download · No registration or login required.
PDF preview
FREE TO VIEW AND DOWNLOAD · NO REGISTRATION OR LOGIN REQUIRED.
Loading PDF…
Normalized SDS data & document analysis
RESDS derives the results below from this document’s extracted text and the site’s same-material index. Detected codes are not reclassified. “Not detected” does not mean “not present”; confirm the original PDF for safety-critical use.
GHS & transport evidence
Page links show the first occurrence found in extracted text.
SDS 16-section coverage
16 section headings detected; 0 not detected by the parser.
Normalized physical-property units
Calculated conversions from values detected in this SDS; not independent laboratory measurements.
| Property | SDS value | SI conversion | US conversion |
|---|---|---|---|
| Melting point | 1021 °C | 1294.15 K | 1869.8 °F |
| Boiling point | 3074 °C | 3347.15 K | 5565.2 °F |
| Density | 7.008 g/cm³ | 7008 kg/m³ | 0.2532 lb/in³ |
Same-material SDS comparison
11 indexed documents · 3 publishers · 1 languages · 5 stated revisions · page range 3–8. This compares document metadata, not product equivalence.
| Publisher | Revision | Language | Region | Pages |
|---|---|---|---|---|
| Current Ames Laboratory, US DOE — Materials Preparation Center | January 26, 2016 | English | United States · OSHA HCS 29 CFR 1910.1200 | 3 |
| Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific) | 26-Jul-2026 | English | United Kingdom | 7 |
| Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific) | 26-Jul-2026 | English | United Kingdom | 7 |
| Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific) | 26-Jul-2026 | English | United Kingdom | 7 |
| Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific) | 26-Jul-2026 | English | United Kingdom | 7 |
| Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific) | 26-Jul-2026 | English | United Kingdom | 7 |
| Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific) | 26-Jul-2026 | English | United Kingdom | 7 |
| Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific) | 31-Jul-2026 | English | United Kingdom | 8 |
Material & document specifications
- Material
- Neodymium metal
- Product / grade
- pieces, ingot, rod, foil, sheet, target
- Publisher
- Ames Laboratory, US DOE — Materials Preparation Center
- Region
- United States · OSHA HCS 29 CFR 1910.1200
- File name
- neodymium-metal-sds-ames-laboratory.pdf
- Document type
- SDS
- CAS reference(s)
- 7440-00-8
- Language
- English
- Original revision
- January 26, 2016
- Pages
- 3
- File size
- 661 KB
- Downloads
- 20
- Date added
- 2026-09-13
Full document text
3 pages · Original document language
Text extracted from the original PDF. Page order and original wording are preserved; tables and symbols may differ from the PDF layout. Check the original PDF for safety-critical details.
Page 1
SDS Safety Data Sheet per 29 CFR 1910.1200 Page 1 of 3 Neodymium
SAFETY DATA SHEET
1 PRODUCT AND SUPPLIER IDENTIFICATION
Product Name: Neodymium - pieces, ingot, rod, foil, sheet, target Formula: Nd
Supplier: Ames Laboratory, US DOE Materials Preparation Center 121 Metals Development Ames, IA 50010 USA Telephone: 515-294-5236 Fax: 515-294-8727 Email: mpc@ameslab.gov Emergency: 515-294-3483 (24 hour) Recommended Uses: Scientific Research
2 HAZARDS IDENTIFICATION
GHS Classification (29 CFR 1910.1200): Not classified as hazardous GHS Label Elements: Signal Word: N/A Hazard Statements: N/A Precautionary Statements: N/A
3 COMPOSITION/INFORMATION ON INGREDIENTS
Ingredient: Neodymium CAS#: 7440-00-8 %: 100 EC#: 231-109-3
4 FIRST AID MEASURES
General Measures: Under normal handling and use, exposure to solid forms of this material present few health hazards. Subsequent operations such as grinding, melting or welding may create dusts or fumes which could be inhaled or contact skin or eyes. INHALATION: Remove to fresh air, keep warm and quiet, give oxygen if breathing is difficult. Seek medical attention. INGESTION: Rinse mouth with water. Do not induce vomiting. Seek medical attention. Never induce vomiting or give anything by mouth to an unconscious person. SKIN: Remove contaminated clothing, brush material off skin, wash affected area with soap and water. Seek medical attention if symptoms persist. EYES: Flush eyes with lukewarm water, including under upper and lower eyelids, for at least 15 minutes. Seek medical attention if symptoms persist.
Most Important Symptoms/Effects, Acute and Delayed: See section 11 for more information. Indication of Immediate Medical Attention and Special Treatment: No other relevant information available.
5 FIREFIGHTING MEASURES
Extinguishing Media: Use Class D dry powder extinguishing agent. Unsuitable Extinguishing Media: Do not use water. Specific Hazards Arising from the Material: Flammable in the form of dust when exposed to heat, spark or flame. May react with water under fire conditions liberating flammable hydrogen gas. May emit fumes of neodymium oxide under fire
Ames Laboratory is operated for the U.S. DOE by Iowa State University, DE-AC02-07CH11358 Page 1 of 3
Page 2
SDS Safety Data Sheet per 29 CFR 1910.1200 Page 2 of 3
conditions. Special Protective Equipment and Precautions for Firefighters: Full face, self-contained breathing apparatus and full protective clothing to prevent contact with skin and eyes.
6 ACCIDENTAL RELEASE MEASURES
Personal Precautions, Protective Equipment, and Emergency Procedures: Wear appropriate respiratory and protective equipment specified in section 8. Isolate spill area. Avoid dust formation. Avoid contact with skin and eyes. Avoid breathing dust or fume. Eliminate all sources of ignition. Methods and Materials for Containment and Cleaning Up: Sweep or scoop spilled product and place in a closed container for further handling and disposal. Use only non-sparking tools and natural bristle brushes. Environmental Precautions: Do not allow to enter drains or to be released to the environment.
7 HANDLING AND STORAGE
Precautions for Safe Handling: Handle in an enclosed, controlled process, under dry protective gas such as argon when possible. Air and moisture sensitive. Protect from sources of ignition. Avoid contact with skin and eyes. Wash thoroughly before eating or smoking. See section 8 for information on personal protection equipment. Conditions for Safe Storage, Including Any Incompatibilities: Neodymium metal should be stored in tightly-closed containers under argon or mineral oil. Store in a cool, dry area. Protect from moisture. See section 10 for more information on incompatible materials.
8 EXPOSURE CONTROLS AND PERSONAL PROTECTION
Exposure Limits: Neodymium OSHA/PEL: No exposure limit established ACGIH/TLV: No exposure limit established Appropriate Engineering Controls: Handle in a humidity controlled atmosphere. Handle in an enclosed, controlled process under dry argon when possible. Ensure adequate ventilation to maintain exposures below occupational limits. Whenever possible the use of local exhaust ventilation or other engineering controls is the preferred method of controlling exposure to airborne dust and fume to meet established occupational exposure limits. Use good housekeeping and sanitation practices. Do not use tobacco or food in work area. Wash thoroughly before eating or smoking. Do not blow dust off clothing or skin with compressed air. Individual Protection Measures, Such as Personal Protective Equipment: Respiratory Protection: If permissible levels are exceeded, use NIOSH approved dust respirator. Eye Protection: Safety glasses Skin Protection: Wear impermeable gloves, protective work clothing as necessary.
9 PHYSICAL AND CHEMICAL PROPERTIES
Appearance: Form: Solid in various forms Color: Silver gray metallic Odor: Not determined Odor Threshold: Not determined pH: N/A Melting Point: 1021 oC Boiling Point: 3074 oC Flash Point: N/A Evaporation Rate: N/A Flammability: No data Upper Flammable Limit: No data Lower Flammable Limit: No data Vapor Pressure: No data Vapor Density: N/A Relative Density (Specific Gravity): 7.008 g/cc Solubility in H2O: Decomposes Partition Coefficient (n-octanol/water): Not determined Autoignition Temperature: No data Decomposition Temperature: No data Viscosity: N/A
Ames Laboratory is operated for the U.S. DOE by Iowa State University, DE-AC02-07CH11358 Page 2 of 3
Page 3
SDS Safety Data Sheet per 29 CFR 1910.1200 Page 3 of 3
10 STABILITY AND REACTIVITY
Reactivity: No data Chemical Stability: Stable under recommended storage conditions. Possibility of Hazardous Reactions:Contact with acids may evolve hydrogen gas. Dusts are flammable. May react with water under fire conditions liberating flammable hydrogen gas. Conditions to Avoid: Avoid creating or accumulating fines or dusts. Incompatible Materials: Air, moisture, acids, acid chlorides, oxidizing agents, halogens, phosphorus, and nitrogen. Hazardous Decomposition Products: Neodymium oxides, neodymium hydroxides, hydrogen.
11 TOXICOLOGICAL INFORMATION
Likely Routes of Exposure: Inhalation, skin, eyes. Product as shipped does not present an inhalation hazard; however subsequent operations may create dusts or fumes which could be inhaled. Symptoms of Exposure: May cause irritation. Acute and Chronic Effects: No data Acute Toxicity: No data Carcinogenicity: NTP: Not identified as carcinogenic IARC: Not identified as carcinogenic To the best of our knowledge the chemical, physical and toxicological characteristics of the substance are not fully known.
12 ECOLOGICAL INFORMATION
Ecotoxicity: No data Persistence and Degradability: No data Bioaccumulative Potential: No data Mobility in Soil: No data Other Adverse Effects: Do not allow material to be released to the environment. No further relevant information available.
13 DISPOSAL CONSIDERATIONS
Waste Disposal Method: Product: Dispose of in accordance with Federal, State and Local regulations. Packaging: Dispose of in accordance with Federal, State and Local regulations.
14 TRANSPORT INFORMATION
DOT/ADR/IATA/IMDG Regulations: Not regulated UN Number: N/A UN Proper Shipping Name: N/A Transport Hazard Class: N/A Packing Group: N/A Marine Pollutant: No Special Precautions: N/A
15 REGULATORY INFORMATION
TSCA Listed: All components are listed. Regulation (EC) No 1272/2008 (CLP): N/A Canada WHMIS Classification (CPR, SOR/88-66): N/A HMIS Ratings: Health: 1 Flammability: 1 Physical: 1 NFPA Ratings: Health: 1 Flammability: 1 Reactivity: 1 Chemical Safety Assessment: A chemical safety assessment has not been carried out.
16 OTHER INFORMATION
The above information is believed to be correct, but does not purport to be all inclusive and shall be used only as a guide. The Materials Preparation Center, Ames Laboratory, and Iowa State University, shall not be held liable for any damages resulting from handling or from contact with the above product and make no warranties, expressed or implied, including, but not limited to, any implied warranty of merchantability or fitness for a particular purpose or course of performance or usage of trade.
Prepared by: The Materials Preparation Center at Ames Laboratory Revised/Reviewed: January 26, 2016
Ames Laboratory is operated for the U.S. DOE by Iowa State University, DE-AC02-07CH11358 Page 3 of 3
Same material — SDS from other publishers
10 documents in this material index. Product grades, hydration states and formulations must be checked in each original PDF.
Neodymium rod SDS
Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific)
English · 26-Jul-2026
PDF · 7 pagesNeodymium foil SDS
Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific)
English · 26-Jul-2026
PDF · 7 pagesNeodymium foil SDS
Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific)
English · 26-Jul-2026
PDF · 7 pagesNeodymium foil SDS
Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific)
English · 26-Jul-2026
PDF · 7 pagesNeodymium rod SDS
Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific)
English · 26-Jul-2026
PDF · 7 pagesNeodymium ingot SDS
Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific)
English · 26-Jul-2026
PDF · 8 pagesNeodymium powder, -40 mesh, 99.8% (REO) SDS
Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific)
English · 31-Jul-2026
PDF · 8 pagesNeodymium powder SDS
Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific)
English · 31-Jul-2026
PDF · 4 pagesNeodymium, Powder SDS
ProChem, Inc.
English · 03/15
PDF · 3 pagesNeodymium, chips SDS
ProChem, Inc.
English · 05/14
Original publisher & company information
Ames Laboratory, US DOE
Record publisher: Ames Laboratory, US DOE — Materials Preparation Center
- Brand / organization
- Ames National Laboratory · MPC
- Country / office
- United States
- Website
- ameslab.gov
- SDS contact email
- mpc@ameslab.gov
- Business phone in SDS
- 515-294-5236
- Product / reference
- pieces, ingot, rod, foil, sheet, target
View extracted supplier details
Supplier: Ames Laboratory, US DOE
Materials Preparation Center
121 Metals Development
Ames, IA 50010 USA
Telephone: 515-294-5236
Fax: 515-294-8727
Email: mpc@ameslab.govAbout Ames Laboratory, US DOE
Ames Laboratory, US DOE is the organization attributed as publisher or supplier of this SDS. See the original identification section and official website for its company profile.
Company website & profileDocument source & record history
Original record: Neodymium (Nd) Metal — Safety Data Sheet (SDS)
Added: 2026-09-13T08:46:19.000Z · Record updated: 2026-09-14T02:29:00.557Z
Original file SHA-256: 99429463201d6ec3e11f56ce291bd9703a6e5794b20022357362613b8a0dc462
Original source PDFReport a correction or request a document update
Report incorrect metadata, extraction errors, a newer supplier version or a rights concern. Reports are stored for the site operator to review; a submission does not immediately change a published SDS.
Your report and optional email are stored privately for handling this request. They are not published on this site. Do not include sensitive information.
Official chemical reference sources
Source guide ↗CAS references recorded in this SDS. Properties below describe individual substances, not necessarily the complete product. Check the original SDS for mixtures, grades and hydrate states.
CAS 7440-00-8Chemical reference & source links
CAS 7440-00-8 · CAS Common Chemistry ↗ · PubChem ↗
- Chemical name (IUPAC)
- View at PubChem ↗
- Molecular formula
- View at PubChem ↗
- Molecular weight
- View at PubChem ↗
- Selected synonyms
- View at PubChem ↗
- Chemical structure
- Open structure at PubChem ↗
Open this reference to retrieve available PubChem properties. Official lookup links remain available.
ECHA CHEM · search CAS 7440-00-8 ↗ · AICIS inventory · search CAS 7440-00-8 ↗
GHS provides classification criteria. The applicable hazard classification must be checked for the specific product and jurisdiction.
Suppliers of this material
Companies identified from matching material SDS and checked official product pages. Confirm grade, formulation and availability with the supplier. Missing contacts are not inferred.
| Company | Country | Website | Phone | Evidence | |
|---|---|---|---|---|---|
| Avocado Research Chemicals Ltd. | United Kingdom | Website | Not stated | +44 (0) 1524 850506 | Source Same material SDS; verify grade and availability |
| ProChem, Inc. | United States | Website | info@prochemonline.com | 815-398-1788 | Source Same material SDS; verify grade and availability |
Search the web for more suppliers
Search this material across search engines
Search query: Neodymium metal SDS
Material background on Wikipedia
Look up Neodymium metal on Wikipedia. A matching article introduction is displayed when available; product-specific mixtures and reference materials may not have a dedicated article.
Find this material on Wikipedia ↗Introduction from Wikipedia contributors; CC BY-SA 4.0. General material background, not a replacement for this product’s SDS.