Praseodymium (III) Chloride Heptahydrate 2966 SDS
Collected by RESDS. Original publisher PDF retained. Original ProChem SDS for Praseodymium (III) Chloride Heptahydrate. Product number 2966; revision 05/15. Publication authorized by the user on 2026-09-14.
PDF preview
FREE TO VIEW AND DOWNLOAD · NO REGISTRATION OR LOGIN REQUIRED.
Loading PDF…
Normalized SDS data & document analysis
RESDS derives the results below from this document’s extracted text and the site’s same-material index. Detected codes are not reclassified. “Not detected” does not mean “not present”; confirm the original PDF for safety-critical use.
GHS & transport evidence
Page links show the first occurrence found in extracted text.
SDS 16-section coverage
14 section headings detected; 2 not detected by the parser.
Material & document specifications
- Material
- Praseodymium (III) Chloride Heptahydrate
- Product / grade
- 2966
- Publisher
- ProChem, Inc.
- Region
- United States
- File name
- prochem-praseodymiumchloride-2966.pdf
- Document type
- SDS
- CAS reference(s)
- 10025-90-8
- Language
- English
- Original revision
- 05/15
- Pages
- 4
- File size
- 880 KB
- Downloads
- 4
- Date added
- 2026-09-14
Full document text
4 pages · Original document language
Text extracted from the original PDF. Page order and original wording are preserved; tables and symbols may differ from the PDF layout. Check the original PDF for safety-critical details.
Page 1
SECTION 1 PRODUCT AND COMPANY INFORMATION
PRODUCT NAME: Praseodymium (III) Chloride Heptahydrate
PRODUCT NUMBER: 2966
CAS NUMBER: 10025-90-8
SYNONYMS: Praseodymium trichloride heptahydrate
MANUFACTURER:
Prochem, Inc. PHONE: 815-398-1788 826 Roosevelt Road FAX: 815-398-1810 Rockford, IL 61109 TOLL FREE: 800-795-8788
IN CASE OF TRANSPORTATION EMERGENCY CONTACT CHEM-TREC: 1-800-424-9300
SECTION 2 HAZARDS IDENTIFICATION
CLASSIFICATION OF SUBSTANCE OR MIXTURE
Pictogram
Signal Word Warning
Hazard Statements
H315 Causes skin irritation. H319 Causes serious eye irritation. H335 May cause respiratory irritation.
Precautionary Phrases
P261 Avoid breathing dust/fume/gas/mist/vapors/spray. P264 Wash skin thoroughly after handling. P271 Use only outdoors or in a well-ventilated area. P280 Wear protective gloves/protective clothing/eye protection/face protection. P302+P352 IF ON SKIN: Wash with plenty of soap and water. P304+P340 IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do. Continue rinsing. P312 Call a POISON CENTER or doctor/physician if you feel unwell. P362 Take off contaminated clothing and wash before reuse. P403+P233 Store in a well-ventilated place. Keep container tightly closed.
HMIS CLASSIFICATION: Health: 2 Fire: 0 Reactivity Hazard: 0 NFPA RATING: Health: 2 Flammability: 0 Reactivity Hazard: 0
PRASEODYMIUM (III) CHLORIDE PAGE 1
Page 2
SECTION 2 HAZARDS IDENTIFICATION (Cont.)
EYE CONTACT: Causes serious eye irritation. SKIN CONTACT: Causes skin irritation. INHALATION: May cause respiratory irritation. INGESTION: No information available on the physiological effects of ingestion in humans.
SECTION 3 COMPOSITION / INFORMATION ON INGREDIENTS
Formula: PrCl3 7H2O
Molecular Weight: 373.37
CHEMICAL NAME CAS# %
Praseodymium (III) Chloride 10025-90-8 100
SECTION 4 FIRST AID MEASURES
EYE EXPOSURE: Immediately flush the eyes with copious amounts of water for at least 15 minutes. Assure flushing under eyelids. A victim may need assistance in keeping their eyelids open. Get immediate competent medical attention. SKIN EXPOSURE: Wash affected area with water. Remove contaminated clothes if necessary. Seek medical assistance if irritation persists. INHALATION: Remove to fresh air and keep at rest. If breathing is difficult, give oxygen. If not breathing, give artificial respiration. Get medical attention. INGESTION: Seek medical assistance immediately. Keep the victim calm. Give the victim water (only if conscious). Induce vomiting only if directed by medical personnel.
SECTION 5 FIREFIGHTING MEASURES
FLASH POINT: Product is not flammable. AUTO IGNITION TEMPERATURE: Not available EXPLOSION LIMITS: Product does not present an explosion hazard. EXTINGUISHING MEDIUM: Use fire fighting measures that suit the surrounding fire. SPECIAL FIRE FIGHTING PROCEDURES: Wear self-contained, approved breathing apparatus and full protective clothing, including eye protection and boots. HAZARDOUS COMBUSTION AND DECOMPOSITION PRODUCTS: Hydrogen chloride gas and praseodymium oxides.
SECTION 6 ACCIDENTAL RELEASE MEASURES
PERSONAL PRECAUTIONS: Wear all appropriate equipment when using this material. Ensure adequate ventilation. Avoid the formation of dust. Avoid breathing vapors, mist, gas, or dust. ENVIRONMENTAL PRECAUTIONS: Prevent spillage from entering drains or allowing to be released into the environment. METHODS AND MATERIALS FOR CONTAINMENT AND CLEANING UP: Mix spills with vermiculite or sodium carbonate powder. Sweep up and place in suitable container for proper disposal.
SECTION 7 HANDLING AND STORAGE
PRECAUTIONS FOR SAFE HANDLING: Wear appropriate personal protective equipment. Avoid contact with skin and eyes. Use with adequate ventilation. Avoid formation of dusts and aerosols. CONDITIONS FOR SAFE STORAGE: Store in cool, dry, and well-ventilated area. Keep away from incompatible materials. Hygroscopic
PRASEODYMIUM (III) CHLORIDE PAGE 2
Page 3
SECTION 8 EXPOSURE CONTROLS AND PERSONAL PROTECTION
EXPOSURE CONTROLS: Contains no substances with occupational exposure limit values. EYE PROTECTION: Wear chemical safety glasses or goggles and face shield. SKIN PROTECTION: Wear nitrile or rubber gloves, and a complete suit protecting against chemicals. VENTILATION: Provide local exhaust, preferably mechanical. RESPIRATOR: Use an approved respirator. ADDITIONAL PROTECTION: Provide eyewash stations, quick-drench showers and washing facilities accessible to areas of use and handling.
SECTION 9 PHYSICAL AND CHEMICAL PROPERTIES
COLOR AND FORM: Green crystal ODOR: None MOLECULAR WEIGHT: 373.77 BOILING POINT: No data available MELTING POINT: No data available SPECIFIC GRAVITY: 2.25 gm/ml VAPOR DENSITY: No data available SOLUBILITY: Soluble
SECTION 10 STABILITY AND REACTIVITY
STABILITY: Hygroscopic HAZARDOUS POLYMERIZATION: Will not occur CONDITIONS TO AVOID: Moisture INCOMPATIBILITY: Strong oxidizing agents and active metals. DECOMPOSITION PRODUCTS: Hydrogen chloride gas and praseodymium oxides.
SECTION 11 TOXICOLOGICAL DATA
ACUTE TOXICITY: LD50 Oral – mouse – 2987mg/kg. CARCINOGENIC EFFECTS: No components of this product present at levels greater than or equal to 0.1% is identified a carcinogen. MUTAGENIC EFFECTS: Not available TETRATOGENIC EFFECTS: Not available CHRONIC TOXICITY: Not available RTECS: TU0175000
To the best of our knowledge the toxicological effects of this compound have not been fully investigated.
SECTION 12 ECOLOGICAL DATA
No information available
SECTION 13 DISPOSAL CONSIDERATIONS
Dispose of in according to local, state, and federal regulations.
SECTION 14 TRANSPORTATION DATA
Not a dangerous good.
PRASEODYMIUM (III) CHLORIDE PAGE 3
Page 4
SECTION 15 REGULATORY INFORMATION
TSCA: Not listed in the TSCA inventory
SARA 302/304: Not Listed
SARA 311/312: Acute Health Hazard
SARA (TITLE 313): Not Listed
CALIFORNIA PROP. 65: Not Listed
MASSACHUSETTS RIGHT TO KNOW COMPONENTS: No components are subject to the Massachusetts Right to Know Act.
NEW JERSEY RIGHT TO KNOW COMPONENTS: Praseodymium(III) chloride
PENNSYLVANIA RIGHT TO KNOW COMPONENTS: Praseodymium(III) chloride
SECTION 16 OTHER INFORMATION
DISCLAIMER: The information herein is believed to be accurate and reliable as of the date compiled. However, Prochem, Inc. makes no representation, warranty, or guarantee of any kind with respect to the information in this document or any use of the product based on the information. DATE PREPARED: 05/15 SDS DEPT.
PRASEODYMIUM (III) CHLORIDE PAGE 4
Same material — SDS from other publishers
0 documents in this material index. Product grades, hydration states and formulations must be checked in each original PDF.
No other publisher PDF is currently indexed for this material.
Original publisher & company information
ProChem, Inc.
- Brand / organization
- ProChem
- Country / office
- United States
- Website
- prochemonline.com
- SDS contact email
- Not stated in SDS
- Business phone in SDS
- 815-398-1788
- Product / reference
- 2966
Official site identifies ProChem, Inc. at 826 Roosevelt Road, Rockford, IL 61109 and publishes its general contact email.
View extracted supplier details
COMPANY INFORMATION PRODUCT NAME: Praseodymium (III) Chloride Heptahydrate PRODUCT NUMBER: 2966 CAS NUMBER: 10025-90-8 SYNONYMS: Praseodymium trichloride heptahydrate MANUFACTURER: Prochem, Inc. PHONE: 815-398-1788 826 Roosevelt Road FAX: 815-398-1810 Rockford, IL 61109 TOLL FREE: 800-795-8788
About ProChem, Inc.
Official site identifies ProChem, Inc. at 826 Roosevelt Road, Rockford, IL 61109 and publishes its general contact email.
Company website & profileDocument source & record history
Original record: Praseodymium (III) Chloride Heptahydrate – ProChem SDS
Added: 2026-09-14T08:14:43.000Z · Record updated: 2026-09-14T09:37:05.650Z
Original file SHA-256: 16a4546826b820d417dfa45f4bc4639c6ef22e446123cd8fdf7408098b5dde93
Original source PDFReport a correction or request a document update
Report incorrect metadata, extraction errors, a newer supplier version or a rights concern. Reports are stored for the site operator to review; a submission does not immediately change a published SDS.
Your report and optional email are stored privately for handling this request. They are not published on this site. Do not include sensitive information.
Official chemical reference sources
Source guide ↗CAS references recorded in this SDS. Properties below describe individual substances, not necessarily the complete product. Check the original SDS for mixtures, grades and hydrate states.
CAS 10025-90-8Chemical reference & source links
CAS 10025-90-8 · CAS Common Chemistry ↗ · PubChem ↗
- Chemical name (IUPAC)
- View at PubChem ↗
- Molecular formula
- View at PubChem ↗
- Molecular weight
- View at PubChem ↗
- Selected synonyms
- View at PubChem ↗
- Chemical structure
- Open structure at PubChem ↗
Open this reference to retrieve available PubChem properties. Official lookup links remain available.
ECHA CHEM · search CAS 10025-90-8 ↗ · AICIS inventory · search CAS 10025-90-8 ↗
GHS provides classification criteria. The applicable hazard classification must be checked for the specific product and jurisdiction.
Suppliers of this material
Companies identified from matching material SDS and checked official product pages. Confirm grade, formulation and availability with the supplier. Missing contacts are not inferred.
No additional supplier has been verified for this material yet.
Search the web for more suppliers
Search this material across search engines
Search query: Praseodymium (III) Chloride Heptahydrate SDS
Material background on Wikipedia
Look up Praseodymium (III) Chloride Heptahydrate on Wikipedia. A matching article introduction is displayed when available; product-specific mixtures and reference materials may not have a dedicated article.
Find this material on Wikipedia ↗Introduction from Wikipedia contributors; CC BY-SA 4.0. General material background, not a replacement for this product’s SDS.