Scandium (III) Iodide 3138 SDS
Collected by RESDS. Original publisher PDF retained. Original manufacturer safety data sheet for Scandium (III) Iodide. Product number: 3138. Original revision: 08/14. Published under the file-level authorization confirmed by the user for the frozen 1,125-file manifest.
PDF preview
FREE TO VIEW AND DOWNLOAD · NO REGISTRATION OR LOGIN REQUIRED.
Loading PDF…
Normalized SDS data & document analysis
RESDS derives the results below from this document’s extracted text and the site’s same-material index. Detected codes are not reclassified. “Not detected” does not mean “not present”; confirm the original PDF for safety-critical use.
GHS & transport evidence
Page links show the first occurrence found in extracted text.
SDS 16-section coverage
14 section headings detected; 2 not detected by the parser.
Normalized physical-property units
Calculated conversions from values detected in this SDS; not independent laboratory measurements.
| Property | SDS value | SI conversion | US conversion |
|---|---|---|---|
| Melting point | 945 °C | 1218.15 K | 1733.0 °F |
Same-material SDS comparison
3 indexed documents · 2 publishers · 1 languages · 3 stated revisions · page range 4–8. This compares document metadata, not product equivalence.
| Publisher | Revision | Language | Region | Pages |
|---|---|---|---|---|
| Current ProChem, Inc. | 08/14 | English | United States | 4 |
| Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific) | 31-Jul-2026 | English | United Kingdom | 8 |
| Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific) | 27-Jul-2026 | English | United Kingdom | 8 |
Material & document specifications
- Material
- Scandium (III) Iodide
- Product / grade
- 3138
- Publisher
- ProChem, Inc.
- Region
- United States
- File name
- prochem-3138.ScandiumIodide.pdf
- Document type
- SDS
- CAS reference(s)
- 14474-33-0
- Language
- English
- Original revision
- 08/14
- Pages
- 4
- File size
- 875 KB
- Downloads
- 6
- Date added
- 2026-09-15
Full document text
4 pages · Original document language
Text extracted from the original PDF. Page order and original wording are preserved; tables and symbols may differ from the PDF layout. Check the original PDF for safety-critical details.
Page 1
SECTION 1 PRODUCT AND COMPANY INFORMATION
PRODUCT NAME: Scandium (III) Iodide
PRODUCT NUMBER: 3138
CAS NUMBER: 14474-33-0
SYNONYMS: Scandium triiodide anhydrous
MANUFACTURER:
Prochem, Inc. PHONE: 815-398-1788 826 Roosevelt Road FAX: 815-398-1810 Rockford, IL 61109 TOLL FREE: 800-795-8788
IN CASE OF TRANSPORTATION EMERGENCY CONTACT CHEM-TREC: 1-800-424-9300
SECTION 2 HAZARDS IDENTIFICATION
CLASSIFICATION OF SUBSTANCE OR MIXTURE
Pictogram
Signal Word Warning
Hazard Statements
H315 Causes skin irritation H319 Causes serious eye irritation H335 May cause respiratory irritation
Precautionary Phrases
P261 Avoid breathing dust/fume/gas/mist/vapors/spray. P264 Wash skin thoroughly after handling. P271 Use only outdoors or in a well-ventilated area. P280 Wear protective gloves/protective clothing/eye protection/face protection P302+P352 IF ON SKIN: Wash with plenty of soap and water. P304+P340 IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. P305+P351+P338 IF IN EYES: Rinse cautiously with waster for several minutes. Remove contact lenses if present and easy to do. Continue rinsing.
HMIS CLASSIFICATION: Health: 1 Fire: 0 Reactivity Hazard: 0 NFPA RATING: Health: 1 Flammability: 0 Reactivity Hazard: 0
SCANDIUM IODIDE PAGE 1
Page 2
SECTION 2 HAZARDS IDENTIFICATION (Cont.)
EYE CONTACT: Causes serious eye irritation. SKIN CONTACT: Causes skin irritation. INHALATION: May cause irritation to respiratory tract. INGESTION: May cause irritation.
SECTION 3 COMPOSITION / INFORMATION ON INGREDIENTS
Formula: ScI3
Molecular Weight: 425.67
CHEMICAL NAME CAS# %
Scandium Iodide 14474-33-0 100
SECTION 4 FIRST AID MEASURES
EYE EXPOSURE: Flush eyes with water for at least 15 minutes. Seek medical attention. SKIN EXPOSURE: Immediately wash with plenty of water and wash soap for at least 15 minutes while removing contaminated clothing. Get medical attention if necessary. INHALATION: Remove to fresh air and keep at rest. If breathing is difficult, give oxygen. If not breathing, give artificial respiration. Get medical attention if necessary. INGESTION: Do NOT induce vomiting. Never give anything by mouth to an unconscious person. If conscious, wash out mouth with water. Get medical attention if necessary.
SECTION 5 FIREFIGHTING MEASURES
FLASH POINT: Product is not flammable AUTO IGNITION TEMPERATURE: Not available EXPLOSION LIMITS: Not available EXTINGUISHING MEDIUM: Use fire fighting measures that suit the surround fire. SPECIAL FIRE FIGHTING PROCEDURES: Wear self-contained, approved breathing apparatus and full protective clothing, including eye protection and boots. HAZARDOUS COMBUSTION AND DECOMPOSITION PRODUCTS: Scandium oxides and hydrogen iodide
SECTION 6 ACCIDENTAL RELEASE MEASURES
PERSONAL PRECAUTIONS: Wear all appropriate equipment when using this material. Ensure adequate ventilation. ENVIRONMENTAL PRECAUTIONS: Prevent spillage from entering drains or allowing to be released into the environment. METHODS AND MATERIALS FOR CONTAINMENT AND CLEANING UP: Isolate spillage. Sweep up and place in suitable container for disposal.
SECTION 7 HANDLING AND STORAGE
PRECAUTIONS FOR SAFE HANDLING: Wear appropriate personal protective equipment. Avoid contact with skin and eyes. Use with adequate ventilation. Wash thoroughly after using. Keep container closed when not in use. Avoid formation of dusts and aerosols. CONDITIONS FOR SAFE STORAGE: Store in cool, dry, and well-ventilated area. Store away from oxidizing agents, water, and moisture. Store under dry inert gas. Hygroscopic. Protect from humidity and water.
SECTION 8 EXPOSURE CONTROLS AND PERSONAL PROTECTION
EXPOSURE CONTROLS: Contains no substances with occupational exposure limit values. EYE PROTECTION: Wear chemical safety glasses or goggles and face shield. SKIN PROTECTION: Wear nitrile or rubber gloves, and a complete suit protecting against chemicals. VENTILATION: Provide local exhaust, preferably mechanical. RESPIRATOR: Use an approved respirator. ADDITIONAL PROTECTION: Provide eyewash stations, quick-drench showers, and washing facilities accessible to areas of use and handling.
SCANDIUM IODIDE PAGE 2
Page 3
SECTION 9 PHYSICAL AND CHEMICAL PROPERTIES
COLOR AND FORM: Yellow or tan powder ODOR: No data available MOLECULAR WEIGHT: 425.67 BOILING POINT: No data available MELTING POINT: 945° C SPECIFIC GRAVITY: No data available VAPOR DENSITY: No data available SOLUBILITY: Soluble
SECTION 10 STABILITY AND REACTIVITY
STABILITY: Stable HAZARDOUS POLYMERIZATION: Will not occur CONDITIONS TO AVOID: Avoid moisture INCOMPATIBILITY: Strong oxidizing agents and strong acids DECOMPOSITION PRODUCTS: Scandium oxides and hydrogen iodide
SECTION 11 TOXICOLOGICAL DATA
ACUTE TOXICITY: Not available CARCINOGENIC EFFECTS: No components of this product present at levels greater than or equal to 0.1% is identified a carcinogen. MUTAGENIC EFFECTS: Not available TETRATOGENIC EFFECTS: Not available
To the best of our knowledge the toxicological effects of this compound have not been fully investigated.
SECTION 12 ECOLOGICAL DATA
No data available.
SECTION 13 DISPOSAL CONSIDERATIONS
Dispose of in according to local, state, and federal regulations.
SECTION 14 TRANSPORTATION DATA
Not a dangerous good.
SECTION 15 REGULATORY INFORMATION
TSCA: Listed in the TSCA inventory
DSCL (EEC): Listed on the DSCL inventory
SARA 302/304: Not Listed
SARA 311/312: Acute Health Hazard, Chronic Health Hazard
SARA (TITLE 313): Not Listed
CALIFORNIA PROP. 65: Not Listed
WHMIS CANADA: Class D-2B: Toxic material causing other toxic effects.
NEW JERSEY RIGHT TO KNOW COMPONENTS: Scandium iodide
PENNSYLVANIA RIGHT TO KNOW COMPONENTS: Scandium iodide
SCANDIUM IODIDE PAGE 3
Page 4
SECTION 16 OTHER INFORMATION
DISCLAIMER: The information herein is believed to be accurate and reliable as of the date compiled. However, Prochem, Inc. makes no representation, warranty, or guarantee of any kind with respect to the information in this document or any use of the product based on the information. DATE PREPARED: 08/14
SCANDIUM IODIDE PAGE 4
Same material — SDS from other publishers
2 documents in this material index. Product grades, hydration states and formulations must be checked in each original PDF.
Scandium (III) iodide ALFAA14477 SDS – Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific)
Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific)
English · 31-Jul-2026
PDF · 8 pagesScandium (III) iodide ALFAA13687 SDS – Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific)
Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific)
English · 27-Jul-2026
Original publisher & company information
ProChem, Inc.
- Brand / organization
- ProChem
- Country / office
- United States
- Website
- prochemonline.com
- SDS contact email
- Not stated in SDS
- Business phone in SDS
- 815-398-1788
- Product / reference
- 3138
Official site identifies ProChem, Inc. at 826 Roosevelt Road, Rockford, IL 61109 and publishes its general contact email.
View extracted supplier details
COMPANY INFORMATION PRODUCT NAME: Scandium (III) Iodide PRODUCT NUMBER: 3138 CAS NUMBER: 14474-33-0 SYNONYMS: Scandium triiodide anhydrous MANUFACTURER: Prochem, Inc. PHONE: 815-398-1788 826 Roosevelt Road FAX: 815-398-1810 Rockford, IL 61109 TOLL FREE: 800-795-8788
About ProChem, Inc.
Official site identifies ProChem, Inc. at 826 Roosevelt Road, Rockford, IL 61109 and publishes its general contact email.
Company website & profileDocument source & record history
Original record: Scandium (III) Iodide SDS – ProChem, Inc.
Added: 2026-09-15T02:46:47.000Z · Record updated: 2026-09-15T02:46:47.826Z
Original file SHA-256: dfebeee5ed3fc9440ec28569c13d45e335df8f6d649ddc6590c2a7b3dd74f228
Original source PDFReport a correction or request a document update
Report incorrect metadata, extraction errors, a newer supplier version or a rights concern. Reports are stored for the site operator to review; a submission does not immediately change a published SDS.
Your report and optional email are stored privately for handling this request. They are not published on this site. Do not include sensitive information.
Official chemical reference sources
Source guide ↗CAS references recorded in this SDS. Properties below describe individual substances, not necessarily the complete product. Check the original SDS for mixtures, grades and hydrate states.
CAS 14474-33-0Chemical reference & source links
CAS 14474-33-0 · CAS Common Chemistry ↗ · PubChem ↗
- Chemical name (IUPAC)
- View at PubChem ↗
- Molecular formula
- View at PubChem ↗
- Molecular weight
- View at PubChem ↗
- Selected synonyms
- View at PubChem ↗
- Chemical structure
- Open structure at PubChem ↗
Open this reference to retrieve available PubChem properties. Official lookup links remain available.
ECHA CHEM · search CAS 14474-33-0 ↗ · AICIS inventory · search CAS 14474-33-0 ↗
GHS provides classification criteria. The applicable hazard classification must be checked for the specific product and jurisdiction.
Suppliers of this material
Companies identified from matching material SDS and checked official product pages. Confirm grade, formulation and availability with the supplier. Missing contacts are not inferred.
| Company | Country | Website | Phone | Evidence | |
|---|---|---|---|---|---|
| Avocado Research Chemicals Ltd. | United Kingdom | Website | Not stated | +44 (0) 1524 850506 | Source Same material SDS; verify grade and availability |
Search the web for more suppliers
Search this material across search engines
Search query: Scandium (III) Iodide SDS
Material background on Wikipedia
Look up Scandium (III) Iodide on Wikipedia. A matching article introduction is displayed when available; product-specific mixtures and reference materials may not have a dedicated article.
Find this material on Wikipedia ↗Introduction from Wikipedia contributors; CC BY-SA 4.0. General material background, not a replacement for this product’s SDS.