RESDSRARE EARTH SDS LIBRARY

Strontium-90 solution with trace yttrium ions | SDS | National Institute of Standards and Technology (NIST) | NIST SRM 4919I | English | 26 June 2015

Collected by RESDS. Original publisher PDF retained. Section 3 explicitly identifies trace yttrium ions (Y+3) and non-radioactive strontium ions (Sr+2). Section 2 identifies the yttrium-90 decay product. This mixed radioactive solution is not a pure yttrium standard. Yttrium CAS and concentration are not stated. Ingredient CAS: hydrochloric acid 7647-01-0; water 7732-18-5. Original publisher: National Institute of Standards and Technology (NIST). Original issue date: 26 June 2015. Reuse basis: https://www.nist.gov/copyrights-disclaimers

Publisher
National Institute of Standards and Technology (NIST)
Document type
SDS
Material
Strontium-90 solution with trace yttrium ions
CAS
Not stated
Product code
NIST SRM 4919I
Language
English
Revision
26 June 2015
Region
United States
Pages
7
Open original PDF

View all PDF documents · Sitemap

YSolution / injectionComposition not fully established
Why this document matches

Composition is not fully established. An unlisted element is not proof of absence.

Y · Composition · Page 2
The solution also contains trace amounts of yttrium ions (Y+3) and non-radioactive strontium ions (Sr+2). Components

Other documented elements: Cl, H, O

Source and record details

Original record title
Strontium-90 Radioactivity Standard with Trace Yttrium - NIST SRM 4919I Safety Data Sheet
Added to RESDS
2026-09-13T14:17:22.000Z
Record updated
2026-09-13T14:17:22.994Z
Original SDS revision
26 June 2015
Original PDF SHA-256
2378e6d015de0f852820c88bc14d2e49cacac5dc2d8292c16fc51dcf1cae8c72

Original publisher/source document

Record dates describe this website, not the supplier’s revision date. Check the original PDF and obtain the applicable current version from its publisher.

Related indexes and classification basis

Report a correction or request a document update

Report incorrect metadata, extraction errors, a newer supplier version or a rights concern. Reports are stored for the site operator to review; a submission does not immediately change a published SDS.

Your report and optional email are stored privately for handling this request. They are not published on this site. Do not include sensitive information.

Full document text

7 pages · Original document language

Text extracted from the original PDF. Page order and original wording are preserved; tables and symbols may differ from the PDF layout. Check the original PDF for safety-critical details.

Page 1

Date of Issue: 26 June 2015

SAFETY DATA SHEET

1. SUBSTANCE AND SOURCE IDENTIFICATION

Product Identifier SRM Number: 4919I SRM Name: Strontium-90 Radioactivity Standard Other Means of Identification: Not applicable.

Recommended Use of This Material and Restrictions of Use This Standard Reference Material (SRM) is intended primarily for the calibration of instruments that are used to measure radioactivity and for the monitoring of radiochemical procedures. A unit of SRM 4919I consists of 5 mL of 1 M (4 %) hydrochloric acid in which a certified quantity of radioactive strontium-90 is dissolved.

Company Information National Institute of Standards and Technology Standard Reference Materials Program 100 Bureau Drive, Stop 2300 Gaithersburg, Maryland 20899-2300

Telephone: 301-975-2200 Emergency Telephone ChemTrec: FAX: 301-948-3730 1-800-424-9300 (North America) E-mail: SRMMSDS@nist.gov +1-703-527-3887 (International) Website: http://www.nist.gov/srm

2. HAZARDS IDENTIFICATION

Radiological Hazard

Warning: THIS MATERIAL SHOULD ONLY BE USED BY PERSONS QUALIFIED TO HANDLE RADIOACTIVE MATERIAL!

SRM 4919I is a radioactive material, strontium-90, with a massic activity of approximately 4 kBq•g-1 in hydrochloric acid. Strontium-90 decays by beta-particle emission to yittrium-90, which also decays by beta particle emission. The beta particles emitted from strontium-90 and yttrium-90 produce bremsstrahlung photons with energies up to 2 MeV.

This product contains licensed radioactive material and is therefore subject to the requirements of 10 CFR Part 20 (e.g., public and occupational exposure limits, waste disposal). At a minimum, the basic radiation safety principles of time, distance, and shielding, and appropriate radiation contamination control should be practiced to avoid/minimize any external and/or internal exposure. Consult with your Radiation Safety office for your facility’s radiation safety requirements/precautions specific to the radionuclide(s) (including its activity and chemical/physical form) in this Radioactive SRM.

Classification Physical Hazard: There are no known physical hazards associated with this material. Health Hazard: Skin Corrosion/Irritation Category 1B Serious Eye Damage/Irritation Category 1

Label Elements Symbol

Signal Word DANGER

Hazard Statement(s) H314 Causes severe skin burns and eye damage.

SRM 4919I Page 1 of 7

Page 2

Precautionary Statement(s) P260 Do not breathe fumes, mists, vapors, or spray. P264 Wash hands thoroughly after handling. P280 Wear protective gloves, protective clothing, and eye protection.

P301+P330+P331 If swallowed: Rinse mouth. Do NOT induce vomiting. P303+P361+P353 If on skin (or hair): Remove immediately all contaminated clothing. Rinse skin with water. P304+P340 If inhaled: Remove person to fresh air and keep comfortable for breathing. P305+P351+P338 If in eyes: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P310 Immediately call a doctor. P363 Wash contaminated clothing before reuse.

P405 Store locked up.

P501 Dispose of contents and container according to local regulations.

Hazards Not Otherwise Classified: None.

Ingredients(s) with Unknown Acute Toxicity: None.

3. COMPOSITION AND INFORMATION ON HAZARDOUS INGREDIENTS

Substance: Strontium-90 in 1 M hydrochloric acid.

Other Designations: Hydrochloric Acid: Muriatic acid; chlorohydric acid; hydrochloride. Strontium-90: Not applicable.

The solution also contains trace amounts of yttrium ions (Y+3) and non-radioactive strontium ions (Sr+2). Components are listed in compliance with OSHA’s 29 CFR 1910.1200; for the actual values see the NIST Certificate.

Hazardous Component(s) CAS Number EC Number Nominal Mass Concentration (EINECS) (%)

Hydrochloric acid 7647-01-0 231-595-7 4 Strontium-90 not applicable not applicable 0.000 000 08 Non-Hazardous Component(s) Water 7732-18-5 231-791-2 96

4. FIRST AID MEASURES

Description of First Aid Measures:

Inhalation: If adverse effects occur, remove to uncontaminated area. If not breathing, give artificial respiration or oxygen by qualified personnel. Seek immediate medical attention.

Skin Contact: Rinse affected area with copious amounts of water followed by washing with soap and water for at least 15 minutes while removing contaminated clothing. Seek medical attention, if needed.

Eye Contact: Immediately flush eyes, including under the eyelids with copious amounts of water for at least 30 minutes. Seek immediate medical attention.

Ingestion: Contact a poison control center immediately for instructions. Wash out mouth with water, but do not induce vomiting. Seek medical aid at once, and bring the container or label.

Most Important Symptoms/Effects, Acute and Delayed: Acid burns to skin and eyes.

Indication of any immediate medical attention and special treatment needed, if necessary: If any of the above symptoms are present, seek immediate medical attention.

5. FIRE FIGHTING MEASURES

Fire and Explosion Hazards: Negligible fire hazard. See Section 9, “Physical and Chemical Properties” for flammability properties.

SRM 4919I Page 2 of 7

Page 3

Extinguishing Media: Suitable: Use extinguishing media appropriate to the surrounding fire. Unsuitable: None listed.

Specific Hazards Arising from the Chemical: Hydrogen chloride.

Special Protective Equipment and Precautions for Fire-Fighters: Avoid inhalation of material or combustion byproducts. Wear full protective clothing and NIOSH approved self-contained breathing apparatus (SCBA).

NFPA Ratings: (0 = Minimal; 1 = Slight; 2 = Moderate; 3 = Serious; 4 = Severe)

Health = 3 Fire = 0 Reactivity = 0

6. ACCIDENTAL RELEASE MEASURES

This material is radioactive. DO NOT touch spilled material. Immediately notify safety personnel of a spill.

Personal Precautions, Protective Equipment, Methods and Materials for Containment and Clean up:

Radiological Emergency Procedures: The following is a guide for first responders. The following actions, including remediation, should be carried out by qualified individuals. In cases where a life-threatening injury occurs concurrent with personal contamination, treat the injury first. Do not touch damaged packages or spilled material. Handle as a radioactive material spill. In addition to those actions described below, the guidelines in the Emergency Response Guidebook (ERG) provide more specific measures that should be followed.

Spill and Leak Control: Alert and clear everyone from the area affected by the spill. Take actions to limit the spread of contamination. Summon aid.

Damage to the Radioactive Source: Evacuate the immediate vicinity around the source. Place a barrier at a safe distance from the source. Identify area as a radiation hazard.

Suggested Emergency Protective Equipment: Gloves Footwear Covers Outer layer or easily removed protective clothing (as situation requires)

7. HANDLING AND STORAGE

Safe Handling Precautions and Storage: This material is radioactive. Store and handle in accordance with all current regulations and standards. See NRC 10 CFR 20 or state regulations. See Section 8, “Exposure Controls and Personal Protection”.

8. EXPOSURE CONTROLS AND PERSONAL PROTECTION

Exposure Limits:

Strontium-90: ALIinh: 20 μCi or 740 kBq (bone surface). See NRC 10 CFR 20 Appendix B. ALIing: 30 μCi or 1.11 MBq (bone surface) OSHA: See OSHA 29 CFR and NRC 10 CFR 20. ACGIH: See International Commission on Radiological Protection guidelines.

Hydrochloric Acid: NIOSH (REL): 7 mg/m3; 5 ppm (Ceiling) 75 mg/m3; 50 ppm (IDLH) ACGIH (TLV): 3 mg/m3; 2 ppm (Ceiling) OSHA (PEL): 7 mg/m3; 5 ppm (Ceiling)

Engineering Controls: Provide local exhaust or process enclosure ventilation system. Ensure compliance with applicable exposure limits.

Personal Protection: In accordance with OSHA 29 CFR 1910.132, subpart I, wear appropriate Personal Protective Equipment (PPE) to minimize exposure to this material.

SRM 4919I Page 3 of 7

Page 4

Respiratory Protection: If workplace conditions warrant a respirator, a respiratory protection program that meets OSHA 29CFR 1910.134 must be followed. Refer to NIOSH 42 CFR 84 for applicable certified respirators.

Eye/Face Protection: Wear splash resistant safety goggles with a face shield. An eye wash station should be readily available near areas of use.

Skin and Body Protection: Wear protective clothing to prevent contact with skin. Wear appropriate gloves.

9. PHYSICAL AND CHEMICAL PROPERTIES

Descriptive Properties: Hydrochloric Acid (4 % of this SRM)

Appearance (physical state, color, etc.): colorless to yellow liquid Molecular Formula: HCl Molar Mass (g/mol): 36.46 Odor: not available Odor threshold: not available pH: <2 Evaporation rate: >1 Melting point/freezing point (ºC): not available Relative Density (g/L) as specific gravity (water = 1): 1 to 1.2 Vapor Pressure (mmHg): not applicable Vapor Density (air = 1): 0.7 (water) Viscosity (cP): 14 mmHg at 20 ºC Solubility(ies): not available Partition coefficient (n-octanol/water): not available

Thermal Stability Properties: Autoignition Temperature (ºC): not applicable Thermal Decomposition (ºC): not applicable Initial boiling point and boiling range (ºC): not available Explosive Limits, LEL (Volume %): not applicable Explosive Limits, UEL (Volume %): not applicable Flash Point (ºC): not applicable Flammability (solid, gas): not applicable

10. STABILITY AND REACTIVITY

Reactivity: Stable at normal temperatures and pressure.

Stability: X Stable Unstable

Possible Hazardous Reactions: None listed.

Conditions to Avoid: Avoid contact with combustible materials and incompatible materials.

Incompatible Materials: Cyanides, metals, amines, bases, metal carbide, oxidizing materials, acids, halo carbons, combustible materials, halogens, metal salts.

Fire/Explosion Information: See Section 5, “Fire Fighting Measures”.

Hazardous Decomposition: Hydrogen chloride.

Hazardous Polymerization: Will Occur X Will Not Occur

11. TOXICOLOGICAL INFORMATION

Route of Exposure: X Inhalation X Skin X Ingestion

Symptoms Related to the Physical, Chemical and Toxicological Characteristics: Burning pain and severe corrosive skin damage. Permanent eye damage including blindness could result.

Potential Health Effects (Acute, Chronic and Delayed):

Inhalation: Hydrochloric acid, if inhaled, can damage the mucous membranes and respiratory tract. Short term exposure may cause irritation and inflammation of the upper respiratory tract, coughing, choking, sore throat,

SRM 4919I Page 4 of 7

Page 5

shortness of breath, headache, dizziness, and nausea. Long term exposure to acid fumes may cause damage to teeth, bronchial irritation, chronic cough, bronchial pneumonia, and gastrointestinal disturbances.

Skin Contact: Hydrochloric acid can cause severe skin burns. Severity of the damage depends on the concentration and duration of exposure. Effects of acid burns may be delayed.

Eye Contact: Hydrochloric acid can cause severe eye irritation, corneal burns, permanent eye damage, or blindness. Severity of the damage depends on the concentration and duration of exposure.

Ingestion: Ingestion of this material is unlikely under normal conditions of use. If ingested, Hydrochloric acid can cause severe burns and damage to the gastrointestinal tract.

Numerical Measures of Toxicity:

Acute Toxicity: Hydrochloric acid, Rat, Inhalation LC50: 3124 ppm (1 h) Rat, Oral LD50: 238 mg/kg to 277 mg/kg Skin Corrosion/Irritation: This SRM contains 4 % hydrochloric acid and it is classified as Category 1.

Serious Eye Damage/Irritation: This SRM contains 4 % hydrochloric acid and it is classified as Category 1.

Respiratory Sensitization: No data available.

Skin Sensitization: No data available.

Germ Cell Mutagenicity: No data available.

Carcinogenicity: No data available.

Listed as a Carcinogen/Potential Carcinogen Yes X No Hydrochloric acid is not listed by NTP, IARC or OSHA as a carcinogen/potential carcinogen.

Radiological Hazard: Strontium-90 Ionizing radiation is a known carcinogen.

Reproductive Toxicity: Not classified. Hydrochloric acid: Rat, Inhalation TCLo: 450 mg/kg (1 h, prior to copulation 1 d)

Specific Target Organ Toxicity, Single Exposure: No data available.

Specific Target Organ Toxicity, Repeated Exposure: No data available.

Aspiration Hazard: No data available.

12. ECOLOGICAL INFORMATION

Ecotoxicity Data: Component: Hydrochloric Acid Fish Toxicity: Mosquitofish (Gambusia affinis) LC50 (static): 282 mg/L (96 h) Invertebrate: Shore crab (Carcinus maenas) LC50 (mortality): 240 mg/L (48 h) Component: Strontium-90 No ecotoxicity data listed.

Persistence and Degradability: No data available.

Bioaccumulative Potential: No data available.

Mobility in Soil: No data available.

Other Adverse Effects: No data available.

13. DISPOSAL CONSIDERATIONS

Waste Disposal: This material is radioactive. Dispose in accordance with all applicable federal, state, and local regulations for RADIOACTIVE materials. See NRC 10 CFR 20 subpart K.

14. TRANSPORTATION INFORMATION

U.S. DOT and IATA: Primary Risk: UN2910, Radioactive Material Excepted Package, Hazard Class 7, PG II. Subsidiary Risk: Hydrochloric acid, Class 8, PG II; Excepted quantity: E2.

SRM 4919I Page 5 of 7

Page 6

15. REGULATORY INFORMATION

U.S. Regulations:

CERCLA Sections 102a/103 (40 CFR 302.4): Hydrochloric acid, 5000 lbs (2270 kg) final RQ.

SARA Title III Section 302 (40 CFR 355.30): Hydrochloric acid, 500 lbs (227 kg) TPQ (gas only).

SARA Title III Section 304 (40 CFR 355.40): Hydrochloric acid, 5000 lbs (2270 kg) EPCRA RQ (gas only).

SARA Title III Section 313 (40 CFR 372.65): Hydrochloric acid, 1.0 % de minimis concentration

(acid aerosols including mists, vapors, gas, fog, and other airborne forms of any particle size).

OSHA Process Safety (29 CFR 1910.119): Not regulated.

SARA Title III Sections 311/312 Hazardous Categories (40 CFR 370.21):

ACUTE HEALTH: Yes. CHRONIC HEALTH: No. FIRE: No. REACTIVE: No. PRESSURE: No.

State Regulations: California Proposition 65: No components are regulated.

U.S. TSCA Inventory: Hydrochloric acid is listed.

TSCA 12(b), Export Notification: No components are listed.

Canadian Regulations: WHMIS Information: Not provided for this material.

16. OTHER INFORMATION

Issue Date: 26 June 2015

Sources: ChemAdvisor, Inc., SDS Hydrochloric Acid, 20 March 2015.

CDC; NIOSH; NIOSH Pocket Guide to Chemical Hazards; Department of Health and Human Services (DHHS), Centers for Disease Control and Prevention (CDC), National Institute for Safety and Health; Hydrochloric Acid, 18 November 2010; available at http://www.cdc.gov/niosh/npg/npgd0447.html (accessed June 2015).

United States National Library of Medicine, Hazardous Substance Database (HSDB), Hydrochloric Acid; available at http://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm (accessed June 2015).

OSHA 29 CFR, Subpart Z, Ionizing radiation, 1910.1096.

NRC 10 CFR 20, Standards for Protection Against Radiation.

DOT 49 CFR 173, Shippers General Requirements for Shipments and Packages.

SRM 4919I Page 6 of 7

Page 7

Key of Acronyms:

ACGIH American Conference of Governmental Industrial NIOSH National Institute for Occupational Safety and Hygienists Health ALI Annual Limit on Intake NIST National Institute of Standards and Technology CAS Chemical Abstracts Service NRC Nuclear Regulatory Commission CEN European Committee for Standardization NTP National Toxicology Program CERCLA Comprehensive Environmental Response, OSHA Occupational Safety and Health Administration Compensation, and Liability Act CFR Code of Federal Regulations PEL Permissible Exposure Limit CPSU Coal Mine Dust Personal Sample Unit RCRA Resource Conservation and Recovery Act DOT Department of Transportation REL Recommended Exposure Limit EC50 Effective Concentration, 50 % RM Reference Material EINECS European Inventory of Existing Commercial RQ Reportable Quantity Chemical Substances EPCRA Emergency Planning and Community Right-to-Know RTECS Registry of Toxic Effects of Chemical Substances Act IARC International Agency for Research on Cancer SARA Superfund Amendments and Reauthorization Act IATA International Air Transportation Agency SCBA Self-Contained Breathing Apparatus IDLH Immediately Dangerous to Life and Health SRM Standard Reference Material ISO International Organization for Standardization STEL Short Term Exposure Limit LC50 Lethal Concentration, 50 % TDLo Toxic Dose Low LD50 Lethal Dose, 50 % TLV Threshold Limit Value LEL Lower Explosive Limit TPQ Threshold Planning Quantity MSDS Material Safety Data Sheet TSCA Toxic Substances Control Act NFPA National Fire Protection Association TWA Time Weighted Average MSHA Mine Safety and Health Administration UEL Upper Explosive Limit WHMIS Workplace Hazardous Materials Information System

Disclaimer: Physical and chemical data contained in this SDS are provided only for use in assessing the hazardous nature of this material. The SDS was prepared carefully, using current references; however, NIST does not certify the data in the SDS. The certified values for this material are given in the NIST Certificate.

Users of this SRM should ensure that the SDS in their possession is current. This can be accomplished by contacting the SRM Program: telephone (301) 975-2200; fax (301) 948-3730; e-mail srmmsds@nist.gov; or via the Internet at http://www.nist.gov/srm.

SRM 4919I Page 7 of 7