Praseodymium powder ALFAA44183 SDS
Collected by RESDS. Original publisher PDF retained. Original manufacturer safety data sheet for Praseodymium powder. Product number: ALFAA44183. Original revision: 27-Jul-2026. Published under the file-level authorization confirmed by the user for the frozen 1,125-file manifest.
PDF preview
FREE TO VIEW AND DOWNLOAD · NO REGISTRATION OR LOGIN REQUIRED.
Loading PDF…
Normalized SDS data & document analysis
RESDS derives the results below from this document’s extracted text and the site’s same-material index. Detected codes are not reclassified. “Not detected” does not mean “not present”; confirm the original PDF for safety-critical use.
GHS & transport evidence
Page links show the first occurrence found in extracted text.
SDS 16-section coverage
16 section headings detected; 0 not detected by the parser.
Normalized physical-property units
Calculated conversions from values detected in this SDS; not independent laboratory measurements.
| Property | SDS value | SI conversion | US conversion |
|---|---|---|---|
| Melting point | 931 °C | 1204.15 K | 1707.8 °F |
| Boiling point | 3127 °C | 3400.15 K | 5660.6 °F |
Same-material SDS comparison
3 indexed documents · 3 publishers · 1 languages · 3 stated revisions · page range 3–8. This compares document metadata, not product equivalence.
| Publisher | Revision | Language | Region | Pages |
|---|---|---|---|---|
| Current Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific) | 27-Jul-2026 | English | United Kingdom | 8 |
| Ames Laboratory, US DOE — Materials Preparation Center | January 26, 2016 | English | United States · OSHA HCS 29 CFR 1910.1200 | 3 |
| ProChem, Inc. | 10/14 | English | United States | 3 |
Material & document specifications
- Material
- Praseodymium powder
- Product / grade
- ALFAA44183
- Publisher
- Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific)
- Region
- United Kingdom
- File name
- thermofisher-ALFAA44183-Praseodymium-EN.pdf
- Document type
- SDS
- CAS reference(s)
- 7440-10-0
- Language
- English
- Original revision
- 27-Jul-2026
- Pages
- 8
- File size
- 73 KB
- Downloads
- 4
- Date added
- 2026-09-15
Why this document matches
Composition is not fully established. An unlisted element is not proof of absence.
Praseodymium 7440-10-0 99.9
Full document text
8 pages · Original document language
Text extracted from the original PDF. Page order and original wording are preserved; tables and symbols may differ from the PDF layout. Check the original PDF for safety-critical details.
Page 1
Page 1 / 8 SAFETY DATA SHEET Revision Date 27-Jul-2026 Version 5
ALFAA44183
Praseodymium powder
SECTION 1. IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING
产品说明:产品说明:产品说明:产品说明: 镨 Product Description: Praseodymium powder
Cat No. : 44183 CAS No 7440-10-0 Molecular Formula Pr
Supplier Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific) Shore Road, Heysham Lancashire, LA3 2XY, United Kingdom Office Tel: +44 (0) 1524 850506 Office Fax: +44 (0) 1524 850608
Emergency Telephone Number For information US call: 001-800-227-6701 / Europe call: +32 14 57 52 11 Emergency Number US:001-201-796-7100 / Europe: +32 14 57 52 99 CHEMTREC Tel. No. US:001-800-424-9300 / Europe:001-703-527-3887
E-mail address begel.sdsdesk@thermofisher.com
Recommended Use Laboratory chemicals. Uses advised against No Information available
SECTION 2. HAZARD IDENTIFICATION
Physical State Appearance Odor Solid Grey No information available
Emergency Overview Flammable solid. Moisture sensitive. Air sensitive. May form combustible dust concentrations in air.
Classification of the substance or mixture
Flammable solids. Category 2
Label Elements
Signal Word Warning
Hazard Statements H228 - Flammable solid
______________________________________________________________________________________________ Page 1
Page 2
ALFAA44183 SAFETY DATA SHEET Revision Date 27-Jul-2026Page 2 / 8 Praseodymium powder ______________________________________________________________________________________________
Precautionary Statements Prevention P210 - Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking P240 - Ground and bond container and receiving equipment P280 - Wear protective gloves/protective clothing/eye protection/face protection Response P370 + P378 - In case of fire: Use dry sand, dry chemical or alcohol-resistant foam to extinguish Storage P403 + P233 - Store in a well-ventilated place. Keep container tightly closed Disposal P501 - Dispose of contents/ container to an approved waste disposal plant
Physical and Chemical Hazards Combustible material. May form combustible dust concentrations in air. Health Hazards The product contains no substances which at their given concentration are considered to be hazardous to health. Environmental hazards Contains no substances known to be hazardous to the environment or not degradable in waste water treatment plants. Will likely be mobile in the environment due to its water solubility. Is not likely mobile in the environment. The product is water soluble, and may spread in water systems. Reacts with water.
May form explosible dust-air mixture if dispersed. This product does not contain any known or suspected endocrine disruptors.
SECTION 3. COMPOSITION/INFORMATION ON INGREDIENTS
Component CAS No Weight % Praseodymium 7440-10-0 99.9
SECTION 4. FIRST AID MEASURES
General Advice If symptoms persist, call a physician.
Eye Contact Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.
Skin Contact Wash off immediately with plenty of water for at least 15 minutes. If skin irritation persists, call a physician.
Inhalation Remove to fresh air. If not breathing, give artificial respiration. Get medical attention if symptoms occur.
Ingestion Clean mouth with water and drink afterwards plenty of water. Get medical attention if symptoms occur.
Most important symptoms and effects None reasonably foreseeable.
Self-Protection of the First Aider Ensure that medical personnel are aware of the material(s) involved, take precautions to protect themselves and prevent spread of contamination.
Notes to Physician Treat symptomatically.
SECTION 5. FIRE-FIGHTING MEASURES
______________________________________________________________________________________________ Page 2
Page 3
ALFAA44183 SAFETY DATA SHEET Revision Date 27-Jul-2026Page 3 / 8 Praseodymium powder ______________________________________________________________________________________________ Suitable Extinguishing Media Dry chemical.
Extinguishing media which must not be used for safety reasons No information available.
Specific Hazards Arising from the Chemical Dust can form an explosive mixture with air. Combustible material. Fine dust dispersed in air may ignite.
Protective Equipment and Precautions for Firefighters As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.
SECTION 6. ACCIDENTAL RELEASE MEASURES
Personal Precautions Ensure adequate ventilation. Use personal protective equipment as required. Avoid dust formation.
Environmental Precautions Should not be released into the environment. Do not allow material to contaminate ground water system. Do not flush into surface water or sanitary sewer system.
Methods for Containment and Clean Up Sweep up and shovel into suitable containers for disposal. Keep in suitable, closed containers for disposal.
Refer to protective measures listed in Sections 8 and 13.
SECTION 7. HANDLING AND STORAGE
Handling Wear personal protective equipment/face protection. Ensure adequate ventilation. Do not get in eyes, on skin, or on clothing. Avoid ingestion and inhalation. Avoid dust formation. Handle under an inert atmosphere.
Storage Keep in a dry, cool and well-ventilated place. Keep container tightly closed. Keep away from heat, sparks and flame. Store contents under argon. Flammables area. Store under an inert atmosphere. Keep container tightly closed in a dry and well-ventilated place. Air sensitive.
Specific Use(s) Use in laboratories
SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Control Parameters
Monitoring methods BS EN 14042:2003 Title Identifier: Workplace atmospheres. Guide for the application and use of procedures for the assessment of exposure to chemical and biological agents. MDHS14/3 General methods for sampling and gravimetric analysis of respirable and inhalable dust
Exposure Controls
Engineering Measures Use explosion-proof electrical/ventilating/lighting equipment. Ensure that eyewash stations and safety showers are close to the workstation location. Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or equipment changes to minimise release or contact, and the use of properly designed ventilation systems, ______________________________________________________________________________________________ Page 3
Page 4
ALFAA44183 SAFETY DATA SHEET Revision Date 27-Jul-2026Page 4 / 8 Praseodymium powder ______________________________________________________________________________________________ should be adopted to control hazardous materials at source.
Personal protective equipment
Eye Protection Goggles (European standard - EN 166)
Hand Protection Protective gloves
Glove material Breakthrough time Glove thickness EU standard Glove comments Natural rubber See manufacturers - EN 374 (minimum requirement) Nitrile rubber recommendations Neoprene PVC Inspect gloves before use. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. (Refer to manufacturer/supplier for information) Ensure gloves are suitable for the task: Chemical compatability, Dexterity, Operational conditions, User susceptibility, e.g. sensitisation effects, also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion. Remove gloves with care avoiding skin contamination.
Skin and body protection Long sleeved clothing
Respiratory Protection When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. To protect the wearer, respiratory protective equipment must be the correct fit and be used and maintained properly
Large scale/emergency use Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced Recommended Filter type: Particulates filter conforming to EN 143
Small scale/Laboratory use Use a NIOSH/MSHA or European Standard EN 149:2001 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended half mask:- Particle filtering: EN149:2001 When RPE is used a face piece Fit Test should be conducted
Hygiene Measures Handle in accordance with good industrial hygiene and safety practice.
Environmental exposure controls No information available.
SECTION 9. PHYSICAL AND CHEMICAL PROPERTIES
Appearance Grey Physical State Solid
Odor No information available Odor Threshold No data available pH No information available Melting Point/Range 931 °C / 1707.8 °F Softening Point No data available Boiling Point/Range 3127 °C / 5660.6 °F Flash Point No information available Method - No information available Evaporation Rate Not applicable Solid Flammability (solid,gas) No information available Explosion Limits No data available
Vapor Pressure No data available Vapor Density Not applicable Solid Specific Gravity / Density No data available Bulk Density No data available Water Solubility Reacts with water ______________________________________________________________________________________________ Page 4
Page 5
ALFAA44183 SAFETY DATA SHEET Revision Date 27-Jul-2026Page 5 / 8 Praseodymium powder ______________________________________________________________________________________________ Solubility in other solvents No information available Partition Coefficient (n-octanol/water) Autoignition Temperature No data available Decomposition Temperature No data available Viscosity Not applicable Solid Explosive Properties No information available Oxidizing Properties No information available
Molecular Formula Pr Molecular Weight 140.91
SECTION 10. STABILITY AND REACTIVITY
Stability Moisture sensitive. Air sensitive.
Hazardous Reactions None under normal processing. Hazardous Polymerization Hazardous polymerization does not occur.
Conditions to Avoid Exposure to air. Incompatible products. Exposure to moist air or water.
Materials to avoid No information available.
Hazardous Decomposition Products Praseodymium oxide.
SECTION 11. TOXICOLOGICAL INFORMATION
Product Information No acute toxicity information is available for this product
(a) acute toxicity;
(b) skin corrosion/irritation; No data available
(c) serious eye damage/irritation; No data available
(d) respiratory or skin sensitization; Respiratory No data available Skin No data available
(e) germ cell mutagenicity; No data available
(f) carcinogenicity; No data available
There are no known carcinogenic chemicals in this product
(g) reproductive toxicity; No data available
(h) STOT-single exposure; No data available
(i) STOT-repeated exposure; No data available
Target Organs No information available.
______________________________________________________________________________________________ Page 5
Page 6
ALFAA44183 SAFETY DATA SHEET Revision Date 27-Jul-2026Page 6 / 8 Praseodymium powder ______________________________________________________________________________________________ (j) aspiration hazard; Not applicable Solid
Other Adverse Effects The toxicological properties have not been fully investigated.
Symptoms / effects,both acute and No information available delayed
SECTION 12. ECOLOGICAL INFORMATION
Ecotoxicity effects Reacts with water so no ecotoxicity data for the substance is available. May cause long-term adverse effects in the environment. Do not allow material to contaminate ground water system.
Persistence and Degradability Product contains heavy metals. Discharge into the environment must be avoided. Special pre-treatment is necessary Persistence based on information available, May persist. Degradability Not relevant for inorganic substances, Reacts with water. Degradation in sewage Water reactive. Contains substances known to be hazardous to the environment or not treatment plant degradable in waste water treatment plants.
Bioaccumulative Potential May have some potential to bioaccumulate
Mobility in soil The product is water soluble, and may spread in water systems Reacts with water Will likely be mobile in the environment due to its water solubility Is not likely mobile in the environment Highly mobile in soils
Endocrine Disruptor Information This product does not contain any known or suspected endocrine disruptors Persistent Organic Pollutant This product does not contain any known or suspected substance Ozone Depletion Potential This product does not contain any known or suspected substance
SECTION 13. DISPOSAL CONSIDERATIONS
Waste from Residues/Unused Waste is classified as hazardous. Dispose of in accordance with the European Directives Products on waste and hazardous waste. Dispose of in accordance with local regulations.
Contaminated Packaging Dispose of this container to hazardous or special waste collection point.
Other Information Waste codes should be assigned by the user based on the application for which the product was used. Do not empty into drains.
SECTION 14. TRANSPORT INFORMATION
Road and Rail Transport
UN-No UN3178 Proper Shipping Name Flammable solid, inorganic, n.o.s. Technical Shipping Name Praseodymium Hazard Class 4.1 Packing Group II
IMDG/IMO
UN-No UN3178
______________________________________________________________________________________________ Page 6
Page 7
ALFAA44183 SAFETY DATA SHEET Revision Date 27-Jul-2026Page 7 / 8 Praseodymium powder ______________________________________________________________________________________________ Proper Shipping Name Flammable solid, inorganic, n.o.s. Technical Shipping Name Praseodymium Hazard Class 4.1 Packing Group II
IATA
UN-No UN3178 Proper Shipping Name Flammable solid, inorganic, n.o.s. Technical Shipping Name Praseodymium Hazard Class 4.1 Packing Group II
Special Precautions for User No special precautions required
SECTION 15. REGULATORY INFORMATION
International Inventories X = listed, China (IECSC), Europe (EINECS/ELINCS/NLP), U.S.A. (TSCA), Canada (DSL/NDSL), Philippines (PICCS), Japan (ENCS), Japan (ISHL), Australia (AICS), Korea (KECL).
Component The List of IECSC EINECS TSCA DSL PICCS ENCS ISHL AICS KECL Inventory of dangerous Hazardous goods GB Chemicals 12268 - (2015 2012 Edition) Praseodymium - - X 231-120-3 X X - X X -
National Regulations
SECTION 16. OTHER INFORMATION
Prepared By Health, Safety and Environmental Department Revision Date 27-Jul-2026 Revision Summary Not applicable.
Training Advice Chemical hazard awareness training, incorporating labelling, Safety Data Sheets (SDS), Personal Protective Equipment (PPE) and hygiene. Use of personal protective equipment, covering appropriate selection, compatibility, breakthrough thresholds, care, maintenance, fit and standards. First aid for chemical exposure, including the use of eye wash and safety showers.
Legend
CAS - Chemical Abstracts Service TSCA - United States Toxic Substances Control Act Section 8(b) Inventory EINECS/ELINCS - European Inventory of Existing Commercial Chemical DSL/NDSL - Canadian Domestic Substances List/Non-Domestic Substances/EU List of Notified Chemical Substances Substances List PICCS - Philippines Inventory of Chemicals and Chemical Substances ENCS - Japanese Existing and New Chemical Substances IECSC - Chinese Inventory of Existing Chemical Substances AICS - Australian Inventory of Chemical Substances KECL - Korean Existing and Evaluated Chemical Substances NZIoC - New Zealand Inventory of Chemicals
WEL - Workplace Exposure Limit TWA - Time Weighted Average ACGIH - American Conference of Governmental Industrial Hygienists IARC - International Agency for Research on Cancer DNEL - Derived No Effect Level PNEC - Predicted No Effect Concentration ______________________________________________________________________________________________ Page 7
Page 8
ALFAA44183 SAFETY DATA SHEET Revision Date 27-Jul-2026Page 8 / 8 Praseodymium powder ______________________________________________________________________________________________ RPE - Respiratory Protective Equipment LD50 - Lethal Dose 50% LC50 - Lethal Concentration 50% EC50 - Effective Concentration 50% NOEC - No Observed Effect Concentration POW - Partition coefficient Octanol:Water PBT - Persistent, Bioaccumulative, Toxic vPvB - very Persistent, very Bioaccumulative
ICAO/IATA - International Civil Aviation Organization/International Air IMO/IMDG - International Maritime Organization/International Maritime Transport Association Dangerous Goods Code ADR - European Agreement Concerning the International Carriage of MARPOL - International Convention for the Prevention of Pollution from Dangerous Goods by Road Ships OECD - Organisation for Economic Co-operation and Development ATE - Acute Toxicity Estimate BCF - Bioconcentration factor VOC - (Volatile Organic Compound)
Key literature references and sources for data https://echa.europa.eu/information-on-chemicals Suppliers safety data sheet, Chemadvisor - LOLI, Merck index, RTECS
Disclaimer The information provided in this Safety Data Sheet is correct to the best of our knowledge, information and belief at the date of its publication. The information given is designed only as a guidance for safe handling, use, processing, storage, transportation, disposal and release and is not to be considered a warranty or quality specification. The information relates only to the specific material designated and may not be valid for such material used in combination with any other materials or in any process, unless specified in the text
End of Safety Data Sheet
______________________________________________________________________________________________ Page 8
Same material — SDS from other publishers
2 documents in this material index. Product grades, hydration states and formulations must be checked in each original PDF.
Original publisher & company information
Avocado Research Chemicals Ltd.
Record publisher: Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific)
- Brand / organization
- Avocado Research Chemicals
- Country / office
- United Kingdom
- Website
- thermofisher.com
- SDS contact email
- Not stated in SDS
- Business phone in SDS
- +44 (0) 1524 850506
- Product / reference
- ALFAA44183
The current official SDS identifies Avocado Research Chemicals Ltd. as part of Thermo Fisher Scientific and gives the Heysham, UK supplier address. No public sales email was confirmed; use the official contact page.
View extracted supplier details
Page 1 / 8 SAFETY DATA SHEET
Revision Date 27-Jul-2026
Version 5
ALFAA44183
Praseodymium powder
SECTION 1. IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING
产品说明:产品说明:产品说明:产品说明: 镨
Product Description: Praseodymium powder
Cat No. : 44183
CAS No 7440-10-0
Molecular Formula Pr
Supplier Avocado Research Chemicals Ltd.
(Part of Thermo Fisher Scientific)
Shore Road, Heysham
Lancashire, LA3 2XY,
United Kingdom
Office Tel: +44 (0) 1524 850506
Office Fax: +44 (0) 1524 850608About Avocado Research Chemicals Ltd.
The current official SDS identifies Avocado Research Chemicals Ltd. as part of Thermo Fisher Scientific and gives the Heysham, UK supplier address. No public sales email was confirmed; use the official contact page.
Company website & profileDocument source & record history
Original record: Praseodymium powder SDS – Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific)
Added: 2026-09-15T02:40:26.000Z · Record updated: 2026-09-15T03:11:49.199Z
Original file SHA-256: bf431a59284bba8201f1619675d806582c4a21acdabdeb9055569c4b24feee7a
Original source PDFReport a correction or request a document update
Report incorrect metadata, extraction errors, a newer supplier version or a rights concern. Reports are stored for the site operator to review; a submission does not immediately change a published SDS.
Your report and optional email are stored privately for handling this request. They are not published on this site. Do not include sensitive information.
Official chemical reference sources
Source guide ↗CAS references recorded in this SDS. Properties below describe individual substances, not necessarily the complete product. Check the original SDS for mixtures, grades and hydrate states.
CAS 7440-10-0Chemical reference & source links
CAS 7440-10-0 · CAS Common Chemistry ↗ · PubChem ↗
- Chemical name (IUPAC)
- View at PubChem ↗
- Molecular formula
- View at PubChem ↗
- Molecular weight
- View at PubChem ↗
- Selected synonyms
- View at PubChem ↗
- Chemical structure
- Open structure at PubChem ↗
Open this reference to retrieve available PubChem properties. Official lookup links remain available.
ECHA CHEM · search CAS 7440-10-0 ↗ · AICIS inventory · search CAS 7440-10-0 ↗
GHS provides classification criteria. The applicable hazard classification must be checked for the specific product and jurisdiction.
Suppliers of this material
Companies identified from matching material SDS and checked official product pages. Confirm grade, formulation and availability with the supplier. Missing contacts are not inferred.
| Company | Country | Website | Phone | Evidence | |
|---|---|---|---|---|---|
| Ames Laboratory, US DOE | United States | Website | mpc@ameslab.gov | 515-294-5236 | Source Same material SDS; verify grade and availability |
| ProChem, Inc. | United States | Website | info@prochemonline.com | 815-398-1788 | Source Same material SDS; verify grade and availability |
Search the web for more suppliers
Search this material across search engines
Search query: Praseodymium powder SDS
Material background on Wikipedia
Look up Praseodymium powder on Wikipedia. A matching article introduction is displayed when available; product-specific mixtures and reference materials may not have a dedicated article.
Find this material on Wikipedia ↗Introduction from Wikipedia contributors; CC BY-SA 4.0. General material background, not a replacement for this product’s SDS.