Page 1
SDS Safety Data Sheet per 29 CFR 1910.1200 Page 1 of 3 Praseodymium
SAFETY DATA SHEET
1 PRODUCT AND SUPPLIER IDENTIFICATION
Product Name: Praseodymium - pieces, ingot, rod, foil (≥0.005"), sheet, target Formula: Pr
Supplier: Ames Laboratory, US DOE Materials Preparation Center 121 Metals Development Ames, IA 50010 USA Telephone: 515-294-5236 Fax: 515-294-8727 Email: mpc@ameslab.gov Emergency: 515-294-3483 (24 hour) Recommended Uses: Scientific Research
2 HAZARDS IDENTIFICATION
GHS Classification (29 CFR 1910.1200): Not classified as hazardous GHS Label Elements: Signal Word: N/A Hazard Statements: N/A Precautionary Statements: N/A
3 COMPOSITION/INFORMATION ON INGREDIENTS
Ingredient: Praseodymium CAS#: 7440-10-0 %: 100 EC#: 231-120-3
4 FIRST AID MEASURES
General Measures: Under normal handling and use, exposure to solid forms of this material present few health hazards. Subsequent operations such as grinding, melting or welding may create dusts or fumes which could be inhaled or contact skin or eyes. INHALATION: Remove to fresh air, keep warm and quiet, give oxygen if breathing is difficult. Seek medical attention. INGESTION: Rinse mouth with water. Do not induce vomiting. Seek medical attention. Never induce vomiting or give anything by mouth to an unconscious person. SKIN: Remove contaminated clothing, brush material off skin, wash affected area with soap and water. Seek medical attention if symptoms persist. EYES: Flush eyes with lukewarm water, including under upper and lower eyelids, for at least 15 minutes. Seek medical attention if symptoms persist.
Most Important Symptoms/Effects, Acute and Delayed: See section 11 for more information. Indication of Immediate Medical Attention and Special Treatment: No other relevant information available.
5 FIREFIGHTING MEASURES
Extinguishing Media: Use Class D dry powder extinguishing agent. Unsuitable Extinguishing Media: Do not use water. Specific Hazards Arising from the Material: May emit fumes of praseodymium oxide under fire conditions. Special Protective Equipment and Precautions for Firefighters: Full face, self-contained breathing apparatus and full
Ames Laboratory is operated for the U.S. DOE by Iowa State University, DE-AC02-07CH11358 Page 1 of 3