Gadolinium(III) fluoride, anhydrous, REacton® ALFAA11293 SDS

Collected by RESDS. Original publisher PDF retained. Original manufacturer safety data sheet for Gadolinium(III) fluoride, anhydrous, REacton®. Product number: ALFAA11293. Original revision: 24-Jul-2026. Published under the file-level authorization confirmed by the user for the frozen 1,125-file manifest.

02 / ORIGINAL PDF

PDF preview

FREE TO VIEW AND DOWNLOAD · NO REGISTRATION OR LOGIN REQUIRED.

Open PDF ↗Download PDFDownload WordDownload TXTDownload MarkdownDownload Excel

Loading PDF…

03 / RESDS DATA ANALYSIS

Normalized SDS data & document analysis

RESDS derives the results below from this document’s extracted text and the site’s same-material index. Detected codes are not reclassified. “Not detected” does not mean “not present”; confirm the original PDF for safety-critical use.

SDS sections16/16
Coverage100%
Hazard codes1
Precautionary codes10
UN numbers1
Same-material docs7

GHS & transport evidence

Page links show the first occurrence found in extracted text.

Hazard statements
H314 p.1
Precautionary statements
P264 p.2P280 p.2P301+P330+P331P303+P361+P353P304+P340P305+P351+P338P310 p.2P362+P364P403 p.2P501 p.2
UN numbers
UN3260 p.6
CAS numbers
13765-26-9 p.1
Signal words
Danger

SDS 16-section coverage

16 section headings detected; 0 not detected by the parser.

1. Identification · detected2. Hazard identification · detected3. Composition / ingredients · detected4. First-aid measures · detected5. Fire-fighting measures · detected6. Accidental release measures · detected7. Handling and storage · detected8. Exposure controls / PPE · detected9. Physical and chemical properties · detected10. Stability and reactivity · detected11. Toxicological information · detected12. Ecological information · detected13. Disposal considerations · detected14. Transport information · detected15. Regulatory information · detected16. Other information · detected

Same-material SDS comparison

7 indexed documents · 6 publishers · 1 languages · 5 stated revisions · page range 4–9. This compares document metadata, not product equivalence.

PublisherRevisionLanguageRegionPages
Current Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific)24-Jul-2026EnglishUnited Kingdom8
Acros-Organics03-May-2012 · Revision 2EnglishEuropean Union · REACH / CLP8
Alfa-Aesar11/24/2015EnglishUnited States · OSHA; Canada · WHMIS5
ProChemNot statedEnglishNot stated4
ProChemNot statedEnglishNot stated4
Sigma-Aldrich09/14/2017 · Version 3.12EnglishNot stated8
Thermo Fisher Scientific22-Dec-2025 · Revision 4EnglishUnited States · OSHA9
SDS publisher documentEXTRACTED RESDS parserCALCULATED deterministic conversion / coverageDERIVED same-material index comparison
04 / SPECIFICATIONS

Material & document specifications

Material
Gadolinium(III) fluoride, anhydrous, REacton®
Product / grade
ALFAA11293
Publisher
Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific)
Region
United Kingdom
File name
thermofisher-ALFAA11293-Gadolinium-EN.pdf
Document type
SDS
CAS reference(s)
13765-26-9
Language
English
Original revision
24-Jul-2026
Pages
8
File size
78 KB
Downloads
3
Date added
2026-09-15
GdFluorideComposition not fully established
Why this document matches

Composition is not fully established. An unlisted element is not proof of absence.

Gd · Composition · Page 2
Gadolinium fluoride (GdF3) 13765-26-9 > 99.9
F · Composition · Page 2
Gadolinium fluoride (GdF3) 13765-26-9 > 99.9

Other documented elements: F

05 / DOCUMENT TEXT

Full document text

8 pages · Original document language

Text extracted from the original PDF. Page order and original wording are preserved; tables and symbols may differ from the PDF layout. Check the original PDF for safety-critical details.

Page 1

Page 1 / 8 SAFETY DATA SHEET Revision Date 24-Jul-2026 Version 6

ALFAA11293

Gadolinium(III) fluoride, anhydrous, REacton®

SECTION 1. IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING

产品说明:产品说明:产品说明:产品说明: 氟化钆(III)氟化钆(III)氟化钆(III)氟化钆(III) Product Description: Gadolinium(III) fluoride, anhydrous, REacton®

Cat No. : 11293 CAS No 13765-26-9 Molecular Formula F3 Gd

Supplier Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific) Shore Road, Heysham Lancashire, LA3 2XY, United Kingdom Office Tel: +44 (0) 1524 850506 Office Fax: +44 (0) 1524 850608

Emergency Telephone Number For information US call: 001-800-227-6701 / Europe call: +32 14 57 52 11 Emergency Number US:001-201-796-7100 / Europe: +32 14 57 52 99 CHEMTREC Tel. No. US:001-800-424-9300 / Europe:001-703-527-3887

E-mail address begel.sdsdesk@thermofisher.com

Recommended Use Laboratory chemicals. Uses advised against No Information available

SECTION 2. HAZARD IDENTIFICATION

Physical State Appearance Odor Powder Solid White Odorless

Emergency Overview Causes severe skin burns and eye damage. Contact with acids liberates toxic gas.

Classification of the substance or mixture

Skin Corrosion/Irritation Category 1 B Serious Eye Damage/Eye Irritation Category 1

Label Elements

Signal Word Danger

Hazard Statements H314 - Causes severe skin burns and eye damage ______________________________________________________________________________________________ Page 1

Page 2

ALFAA11293 SAFETY DATA SHEET Revision Date 24-Jul-2026Page 2 / 8 Gadolinium(III) fluoride, anhydrous, REacton® ______________________________________________________________________________________________

Precautionary Statements Prevention P264 - Wash face, hands and any exposed skin thoroughly after handling P280 - Wear protective gloves/protective clothing/eye protection/face protection Response P301 + P330 + P331 - IF SWALLOWED: rinse mouth. Do NOT induce vomiting P303 + P361 + P353 - IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water or shower P304 + P340 - IF INHALED: Remove person to fresh air and keep comfortable for breathing P305 + P351 + P338 - IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing P310 - Immediately call a POISON CENTER or doctor P362 + P364 - Take off contaminated clothing and wash it before reuse Storage P403 - Store in a well-ventilated place Disposal P501 - Dispose of contents/ container to an approved waste disposal plant

Physical and Chemical Hazards Contact with acids liberates toxic gas. Health Hazards Corrosive. Causes skin and eye burns. Environmental hazards Contains no substances known to be hazardous to the environment or not degradable in waste water treatment plants. Is not likely mobile in the environment due its low water solubility. Spillage unlikely to penetrate soil.

This product does not contain any known or suspected endocrine disruptors.

SECTION 3. COMPOSITION/INFORMATION ON INGREDIENTS

Component CAS No Weight % Gadolinium fluoride (GdF3) 13765-26-9 > 99.9

SECTION 4. FIRST AID MEASURES

Eye Contact Immediate medical attention is required. Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes.

Skin Contact Wash off immediately with soap and plenty of water while removing all contaminated clothes and shoes. Immediate medical attention is required.

Inhalation Remove from exposure, lie down. Remove to fresh air. If not breathing, give artificial respiration. Immediate medical attention is required.

Ingestion Do NOT induce vomiting. Call a physician immediately.

Most important symptoms and effects Causes burns by all exposure routes. Product is a corrosive material. Use of gastric lavage or emesis is contraindicated. Possible perforation of stomach or esophagus should be investigated: Ingestion causes severe swelling, severe damage to the delicate tissue and danger of perforation

Self-Protection of the First Aider Ensure that medical personnel are aware of the material(s) involved, take precautions to protect themselves and prevent spread of contamination.

Notes to Physician

______________________________________________________________________________________________ Page 2

Page 3

ALFAA11293 SAFETY DATA SHEET Revision Date 24-Jul-2026Page 3 / 8 Gadolinium(III) fluoride, anhydrous, REacton® ______________________________________________________________________________________________ Treat symptomatically.

SECTION 5. FIRE-FIGHTING MEASURES

Suitable Extinguishing Media Carbon dioxide (CO 2). Dry chemical. Chemical foam.

Extinguishing media which must not be used for safety reasons No information available.

Specific Hazards Arising from the Chemical Thermal decomposition can lead to release of irritating gases and vapors.

Protective Equipment and Precautions for Firefighters As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.

SECTION 6. ACCIDENTAL RELEASE MEASURES

Personal Precautions Ensure adequate ventilation.

Environmental Precautions See Section 12 for additional Ecological Information.

Methods for Containment and Clean Up Avoid dust formation. Sweep up and shovel into suitable containers for disposal. Do not let this chemical enter the environment.

Refer to protective measures listed in Sections 8 and 13.

SECTION 7. HANDLING AND STORAGE

Handling Do not breathe dust. Do not get in eyes, on skin, or on clothing. Do not ingest. If swallowed then seek immediate medical assistance. Handle product only in closed system or provide appropriate exhaust ventilation.

Storage Keep in a dry, cool and well-ventilated place. Keep container tightly closed. Keep away from acids. Corrosives area. Keep containers tightly closed in a dry, cool and well-ventilated place.

Specific Use(s) Use in laboratories

SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION

Control Parameters

Component China ACGIH TLV OSHA PEL NIOSH Gadolinium fluoride (GdF3) - TWA: 2.5 mg/m3 (Vacated) TWA: 2.5 mg/m3 IDLH: 250 mg/m3

Component Hong Kong Thailand European Union The United Kingdom Gadolinium fluoride (GdF3) - TWA: 2.5 mg/m3 -

Legend

ACGIH - American Conference of Governmental Industrial Hygienists OSHA - Occupational Safety and Health Administration

______________________________________________________________________________________________ Page 3

Page 4

ALFAA11293 SAFETY DATA SHEET Revision Date 24-Jul-2026Page 4 / 8 Gadolinium(III) fluoride, anhydrous, REacton® ______________________________________________________________________________________________ Monitoring methods BS EN 14042:2003 Title Identifier: Workplace atmospheres. Guide for the application and use of procedures for the assessment of exposure to chemical and biological agents. MDHS14/3 General methods for sampling and gravimetric analysis of respirable and inhalable dust

Exposure Controls

Engineering Measures Ensure adequate ventilation, especially in confined areas. Ensure that eyewash stations and safety showers are close to the workstation location. Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or equipment changes to minimise release or contact, and the use of properly designed ventilation systems, should be adopted to control hazardous materials at source.

Personal protective equipment

Eye Protection Goggles (European standard - EN 166)

Hand Protection Protective gloves

Glove material Breakthrough time Glove thickness EU standard Glove comments Natural rubber See manufacturers - EN 374 (minimum requirement) Nitrile rubber recommendations Neoprene PVC Inspect gloves before use. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. (Refer to manufacturer/supplier for information) Ensure gloves are suitable for the task: Chemical compatability, Dexterity, Operational conditions, User susceptibility, e.g. sensitisation effects, also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion. Remove gloves with care avoiding skin contamination.

Skin and body protection Wear appropriate protective gloves and clothing to prevent skin exposure

Respiratory Protection When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. To protect the wearer, respiratory protective equipment must be the correct fit and be used and maintained properly

Large scale/emergency use Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced Recommended Filter type: Particulates filter conforming to EN 143

Small scale/Laboratory use Use a NIOSH/MSHA or European Standard EN 149:2001 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended half mask:- Particle filtering: EN149:2001 When RPE is used a face piece Fit Test should be conducted

Hygiene Measures Handle in accordance with good industrial hygiene and safety practice.

Environmental exposure controls No information available.

SECTION 9. PHYSICAL AND CHEMICAL PROPERTIES

Appearance White Physical State Powder Solid

Odor Odorless Odor Threshold No data available pH No information available Melting Point/Range No data available Softening Point No data available ______________________________________________________________________________________________ Page 4

Page 5

ALFAA11293 SAFETY DATA SHEET Revision Date 24-Jul-2026Page 5 / 8 Gadolinium(III) fluoride, anhydrous, REacton® ______________________________________________________________________________________________ Boiling Point/Range No information available Flash Point No information available Method - No information available Evaporation Rate Not applicable Solid Flammability (solid,gas) No information available Explosion Limits No data available

Vapor Pressure No information available Vapor Density Not applicable Solid Specific Gravity / Density No data available Bulk Density No data available Water Solubility Insoluble Solubility in other solvents No information available Partition Coefficient (n-octanol/water) Autoignition Temperature No data available Decomposition Temperature No data available Viscosity Not applicable Solid Explosive Properties No information available Oxidizing Properties No information available

Molecular Formula F3 Gd Molecular Weight 214.24

SECTION 10. STABILITY AND REACTIVITY

Stability Stable under normal conditions.

Hazardous Reactions No information available. Hazardous Polymerization No information available.

Conditions to Avoid Avoid dust formation. Incompatible products.

Materials to avoid Acids. Strong oxidizing agents. Strong reducing agents.

Hazardous Decomposition Products Gaseous hydrogen fluoride (HF).

SECTION 11. TOXICOLOGICAL INFORMATION

Product Information No acute toxicity information is available for this product

(a) acute toxicity;

(b) skin corrosion/irritation; Category 1 B

(c) serious eye damage/irritation; No data available

(d) respiratory or skin sensitization; Respiratory No data available Skin No data available

(e) germ cell mutagenicity; No data available

(f) carcinogenicity; No data available

There are no known carcinogenic chemicals in this product

______________________________________________________________________________________________ Page 5

Page 6

ALFAA11293 SAFETY DATA SHEET Revision Date 24-Jul-2026Page 6 / 8 Gadolinium(III) fluoride, anhydrous, REacton® ______________________________________________________________________________________________ (g) reproductive toxicity; No data available

(h) STOT-single exposure; No data available

(i) STOT-repeated exposure; No data available

Target Organs No information available.

(j) aspiration hazard; Not applicable Solid

Other Adverse Effects The toxicological properties have not been fully investigated.

Symptoms / effects,both acute and Product is a corrosive material. Use of gastric lavage or emesis is contraindicated. delayed Possible perforation of stomach or esophagus should be investigated: Ingestion causes severe swelling, severe damage to the delicate tissue and danger of perforation

SECTION 12. ECOLOGICAL INFORMATION

Ecotoxicity effects Do not empty into drains.

Persistence and Degradability Persistence Insoluble in water. Degradability Not relevant for inorganic substances.

Bioaccumulative Potential May have some potential to bioaccumulate

Mobility in soil Spillage unlikely to penetrate soil Is not likely mobile in the environment due its low water solubility

Endocrine Disruptor Information This product does not contain any known or suspected endocrine disruptors Persistent Organic Pollutant This product does not contain any known or suspected substance Ozone Depletion Potential This product does not contain any known or suspected substance

SECTION 13. DISPOSAL CONSIDERATIONS

Waste from Residues/Unused Waste is classified as hazardous. Dispose of in accordance with the European Directives Products on waste and hazardous waste. Dispose of in accordance with local regulations.

Contaminated Packaging Dispose of this container to hazardous or special waste collection point.

Other Information Waste codes should be assigned by the user based on the application for which the product was used. Do not empty into drains. Do not flush to sewer. Large amounts will affect pH and harm aquatic organisms.

SECTION 14. TRANSPORT INFORMATION

Road and Rail Transport

UN-No UN3260 Proper Shipping Name Corrosive solid, acidic, inorganic, n.o.s. Hazard Class 8 ______________________________________________________________________________________________ Page 6

Page 7

ALFAA11293 SAFETY DATA SHEET Revision Date 24-Jul-2026Page 7 / 8 Gadolinium(III) fluoride, anhydrous, REacton® ______________________________________________________________________________________________ Packing Group III

IMDG/IMO

UN-No UN3260 Proper Shipping Name Corrosive solid, acidic, inorganic, n.o.s. Hazard Class 8 Packing Group III

IATA

UN-No UN3260 Proper Shipping Name CORROSIVE SOLID, ACIDIC, INORGANIC, N.O.S.* Hazard Class 8 Packing Group III

Special Precautions for User No special precautions required

SECTION 15. REGULATORY INFORMATION

International Inventories X = listed, China (IECSC), Europe (EINECS/ELINCS/NLP), U.S.A. (TSCA), Canada (DSL/NDSL), Philippines (PICCS), Japan (ENCS), Japan (ISHL), Australia (AICS), Korea (KECL).

Component The List of IECSC EINECS TSCA DSL PICCS ENCS ISHL AICS KECL Inventory of dangerous Hazardous goods GB Chemicals 12268 - (2015 2012 Edition) Gadolinium fluoride - - - 237-369-4 X - - X X - KE-17398 (GdF3)

National Regulations

SECTION 16. OTHER INFORMATION

Prepared By Health, Safety and Environmental Department Revision Date 24-Jul-2026 Revision Summary Not applicable.

Training Advice Chemical hazard awareness training, incorporating labelling, Safety Data Sheets (SDS), Personal Protective Equipment (PPE) and hygiene. Use of personal protective equipment, covering appropriate selection, compatibility, breakthrough thresholds, care, maintenance, fit and standards. First aid for chemical exposure, including the use of eye wash and safety showers.

Legend

CAS - Chemical Abstracts Service TSCA - United States Toxic Substances Control Act Section 8(b) Inventory EINECS/ELINCS - European Inventory of Existing Commercial Chemical DSL/NDSL - Canadian Domestic Substances List/Non-Domestic Substances/EU List of Notified Chemical Substances Substances List PICCS - Philippines Inventory of Chemicals and Chemical Substances ENCS - Japanese Existing and New Chemical Substances IECSC - Chinese Inventory of Existing Chemical Substances AICS - Australian Inventory of Chemical Substances KECL - Korean Existing and Evaluated Chemical Substances NZIoC - New Zealand Inventory of Chemicals ______________________________________________________________________________________________ Page 7

Page 8

ALFAA11293 SAFETY DATA SHEET Revision Date 24-Jul-2026Page 8 / 8 Gadolinium(III) fluoride, anhydrous, REacton® ______________________________________________________________________________________________

WEL - Workplace Exposure Limit TWA - Time Weighted Average ACGIH - American Conference of Governmental Industrial Hygienists IARC - International Agency for Research on Cancer DNEL - Derived No Effect Level PNEC - Predicted No Effect Concentration RPE - Respiratory Protective Equipment LD50 - Lethal Dose 50% LC50 - Lethal Concentration 50% EC50 - Effective Concentration 50% NOEC - No Observed Effect Concentration POW - Partition coefficient Octanol:Water PBT - Persistent, Bioaccumulative, Toxic vPvB - very Persistent, very Bioaccumulative

ICAO/IATA - International Civil Aviation Organization/International Air IMO/IMDG - International Maritime Organization/International Maritime Transport Association Dangerous Goods Code ADR - European Agreement Concerning the International Carriage of MARPOL - International Convention for the Prevention of Pollution from Dangerous Goods by Road Ships OECD - Organisation for Economic Co-operation and Development ATE - Acute Toxicity Estimate BCF - Bioconcentration factor VOC - (Volatile Organic Compound)

Key literature references and sources for data https://echa.europa.eu/information-on-chemicals Suppliers safety data sheet, Chemadvisor - LOLI, Merck index, RTECS

Disclaimer The information provided in this Safety Data Sheet is correct to the best of our knowledge, information and belief at the date of its publication. The information given is designed only as a guidance for safe handling, use, processing, storage, transportation, disposal and release and is not to be considered a warranty or quality specification. The information relates only to the specific material designated and may not be valid for such material used in combination with any other materials or in any process, unless specified in the text

End of Safety Data Sheet

______________________________________________________________________________________________ Page 8

06 / OTHER PUBLISHERS

Same material — SDS from other publishers

6 documents in this material index. Product grades, hydration states and formulations must be checked in each original PDF.

07 / SOURCE COMPANY

Original publisher & company information

Supplier / publisher listed in SDS

Avocado Research Chemicals Ltd.

Record publisher: Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific)

Official website checked
Brand / organization
Avocado Research Chemicals
Country / office
United Kingdom
SDS contact email
Not stated in SDS
Business phone in SDS
+44 (0) 1524 850506
Product / reference
ALFAA11293
Official website contactContact page / website Source · Checked 2026-09-15

The current official SDS identifies Avocado Research Chemicals Ltd. as part of Thermo Fisher Scientific and gives the Heysham, UK supplier address. No public sales email was confirmed; use the official contact page.

View extracted supplier details
Page 1 / 8             SAFETY DATA SHEET
                                                                                                     Revision Date 24-Jul-2026
                                                                                                                   Version 6


 ALFAA11293

                Gadolinium(III) fluoride, anhydrous, REacton®

   SECTION 1. IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING


产品说明:产品说明:产品说明:产品说明:                   氟化钆(III)氟化钆(III)氟化钆(III)氟化钆(III)
Product Description:                Gadolinium(III) fluoride, anhydrous, REacton®

Cat No. :                        11293
CAS No                           13765-26-9
Molecular Formula               F3 Gd

Supplier                         Avocado Research Chemicals Ltd.
                                        (Part of Thermo Fisher Scientific)
                                 Shore Road, Heysham
                                     Lancashire, LA3 2XY,
                                    United Kingdom
                                        Office Tel: +44 (0) 1524 850506
                                        Office Fax: +44 (0) 1524 850608

About Avocado Research Chemicals Ltd.

The current official SDS identifies Avocado Research Chemicals Ltd. as part of Thermo Fisher Scientific and gives the Heysham, UK supplier address. No public sales email was confirmed; use the official contact page.

Company website & profile
Document source & record history

Original record: Gadolinium(III) fluoride, anhydrous, REacton® SDS – Avocado Research Chemicals Ltd. (Part of Thermo Fisher Scientific)

Added: 2026-09-15T02:44:18.000Z · Record updated: 2026-09-15T03:11:49.199Z

Original file SHA-256: cf492d90cb94c6dbb635973a5002a3c7b37d1d02f5bc198f2c835b69fe49dc90

Original source PDF

Report a correction or request a document update

Report incorrect metadata, extraction errors, a newer supplier version or a rights concern. Reports are stored for the site operator to review; a submission does not immediately change a published SDS.

Your report and optional email are stored privately for handling this request. They are not published on this site. Do not include sensitive information.

08 / OFFICIAL REFERENCES

Official chemical reference sources

Source guide ↗

CAS references recorded in this SDS. Properties below describe individual substances, not necessarily the complete product. Check the original SDS for mixtures, grades and hydrate states.

CAS 13765-26-9Chemical reference & source links
Chemical name (IUPAC)
View at PubChem ↗
Molecular formula
View at PubChem ↗
Molecular weight
View at PubChem ↗
Selected synonyms
View at PubChem ↗

Open this reference to retrieve available PubChem properties. Official lookup links remain available.

GHS provides classification criteria. The applicable hazard classification must be checked for the specific product and jurisdiction.

09 / MATERIAL SUPPLIERS

Suppliers of this material

Companies identified from matching material SDS and checked official product pages. Confirm grade, formulation and availability with the supplier. Missing contacts are not inferred.

CompanyCountryWebsiteEmailPhoneEvidence
Acros Organics BVBABelgiumWebsite begel.sdsdesk@thermofisher.comNot statedSource Same material SDS; verify grade and availability
ProChemUnited StatesWebsite Not stated815-398-1788Source Same material SDS; verify grade and availability
Sigma-AldrichUnited StatesWebsite Not stated+1 800-325-5832Source Same material SDS; verify grade and availability
Search the web for more suppliers
10 / GLOBAL SEARCH

Search this material across search engines

Search query: Gadolinium(III) fluoride, anhydrous, REacton® SDS

11 / WIKIPEDIA

Material background on Wikipedia

Look up Gadolinium(III) fluoride, anhydrous, REacton® on Wikipedia. A matching article introduction is displayed when available; product-specific mixtures and reference materials may not have a dedicated article.

Find this material on Wikipedia ↗

Access logs & privacy